• Research into Treatments for Ebola Virus and Haemorrhagic Diseases drives Higher Demand for BSCs with Maximum Protection

Laboratory Products

Research into Treatments for Ebola Virus and Haemorrhagic Diseases drives Higher Demand for BSCs with Maximum Protection

Oct 21 2014

Telstar has increased its production of Class III Biological Safety Cabinets by 80% throughout the year 2014 in response to the growing international demand, especially from laboratories and R&D centres located in several African countries. These type of cabinets have been designed for working with highly infectious microbiological agents (classified as Biosafety Level 4 (BSL-4)) and for conducting hazardous operations and provides maximum protection for the environment and the user.

The Telstar Class III Biological Safety Cabinets, which are designed and manufactured at its Technology Centre for medical-hospital technologies, located in the Netherlands, provide a totally contained area to protect the worker, the work and the environment. The Telstar cabinet features a fully sealed, air-tight working area which keeps the user completely isolated from the product by a physical barrier, with the sample being handled using gloves attached through the sealed window of the cabinet. The level of the leak tightness is in accordance with the international standard EN12469 and the cabinet is kept under pressure of -200Pa in the working area to ensure that maximum protection is provided. In case of incident, security measures are activated. For example, if a glove is torn there will still be a minimum airflow of 0,7m/s into the isolator through the open glove so safety is maintained even with one glove totally removed. In addition, a HEPA-H14 filter located in the rear part of the cabinet continuously supplies filtered air to the working chamber and the evacuated air is passed through another HEPA-H14 filter, preventing the release of microorganisms into the environment. In accordance with the cabinet design, the HEPA-H14 supply filter provides turbulent flow within the cabinet. Airflow is maintained by an exhaust system exterior to the cabinet, which keeps the cabinet under negative pressure. Materials are placed inside the cabinet using a pass-through box with a double sealed door, which can be decontaminated between uses.Research into Treatments for Ebola Virus and Haemorrhagic Diseases drives Higher Demand for BSCs with Maximum Protection


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

Lab Indonesia

Apr 24 2024 Jakarta, Indonesia

Expomed Eurasia

Apr 25 2024 Istanbul, Turkey

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

SETAC Europe

May 05 2024 Seville, Spain

InformEx Zone at CPhl North America

May 07 2024 Pennsylvania, PA, USA

View all events