Reaction Monitoring Experiments for Benchtop NMR Spectrometers Announced
Jul 24 2014
The Magritek Spinsolve high-resolution benchtop NMR spectrometer can be installed directly in a fume hood of a chemistry lab to monitor the progress of chemical reactions on-line. Reactants can be pumped in continuous mode from the reactor to the magnet and back using standard PTFE tubing.
The reaction itself can be carried out at temperatures of up to about 100°C. When the reaction mixture is pumped through the bore of the magnet using 2 mm o. d. PTFE tubing, it naturally cools down to 30°C or lower as it flows along the length of the tubing at room temperature. For reactions where maintaining the elevated temperature is critical, Magritek has put together a simple but effective flow set-up for on-line monitoring. It comprises a Dewar of 5 mm o. d. and 2.25 mm i. d. that is mounted in the bore of the Spinsolve to minimise any heat transfer from the flowing sample to the magnet. The pump, which can be set to operate in continuous or stop-flow mode to acquire points with a time resolution of about 15 seconds, is placed in the flow-loop after the magnet in order to minimise the tubing length that goes from the reactor to the sensitive volume of the Spinsolve.
This approach to reaction monitoring has been demonstrated on a number of classical chemical reactions. For example, acetalisation is a common reaction in organic synthesis where an acetal is produced from an aldehyde and an alcohol. In the example here, acetaldehyde reacts with methanol to produce acetaldehyde dimethyl acetal. The reaction was performed in DMSO to prevent evaporation. With data being collected every fifteen seconds over a total period of one hour, the user could follow waterfall plots to show the decrease of acetaldehyde as it was used up together with the corresponding rise of the acetaldehyde dimethyl acetal.
These and many other reaction systems are described in the growing library of applications notes and case studies which are freely available for downloading from the Magritek website.
Digital Edition
Lab Asia 31.2 April 2024
April 2024
In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...
View all digital editions
Events
Microbiology Society Annual Conference 2024
Apr 08 2024 Edinburgh 2024
Apr 09 2024 Munich, Germany
Apr 10 2024 Helsinki, Finland
Analytica Anacon India & IndiaLabExpo
Apr 15 2024 Mumbai, India
Apr 16 2024 Moscow, Russia