• The best choice for poly(dT) oligonucleotide analysis – YMC-Triart Bio C18 columns
    Figure 1: Structure of poly(dT) oligonucleotides with thymine as bases.
  • Figure 2: Comparison of poly(dT) oligonucleotides separation by IP-RP using YMC-Triart Bio C18,XBridge Oligonucleotide BEH C18 and DNAPac RP.
  • Figure 3: Peak area of poly(dT) oligonucleotides of up to 6 repeated analyses, separated by IP-RP using YMC-Triart Bio C18 and DNAPac RP from Thermo Fisher Scientific Inc.

HPLC, UHPLC

The best choice for poly(dT) oligonucleotide analysis – YMC-Triart Bio C18 columns

Apr 25 2023

Poly(dT) oligonucleotides are single stranded nucleotide chains, which solely consist of thymine as bases. Due to base pairing of thymine and adenine, poly(dT) oligonucleotides are able to capture polyadenylated messenger RNA (mRNA). This mechanism is widely used during mRNA extraction and purification, for instance in the course of complementary DNA (cDNA) synthesis or mRNA vaccine manufacturing. Therefore, the need for high purity oligonucleotides is of paramount importance.

For analysis of oligonucleotides, ion pair reversed phase (IP-RP) high performance liquid chromatography (HPLC) is the most common method used. IP-RP relies on the ionic interaction between the analyte and the ion-pair reagent. The lipophilic alkyl chain of the ion pair reagent has high affinity to the stationary phase, which maximises the retention of analytes on the phase. Due to the high resolution of IP-RP chromatography, oligonucleotides with only minimal size differences can be separated.

Comparison with 2 dedicated oligonucleotide columns

In this technical note, a YMC-Triart Bio C18 column is compared with a XBridge Oligonucleotide BEH C18 and a DNAPac column, which are claimed to be specially designed for the separation of oligonucleotides. The YMC-Triart Bio C18 column demonstrates a better resolution, higher recovery and reproducibility of poly(dT) oligonucleotides compared to the XBridge Oligonucleotide BEH C18 and DNAPac RP columns (figure 2 and 3).

Better resolution, recovery and reproducibility

Longer poly(dT) oligonucleotides (60–120mer) were separated poorly by XBridge Oligonucleotide BEH C18, whereas YMC-Triart showed high resolution for oligonucleotides of all sizes (figure 2). Peak areas and therefore recoveries of shorter poly(dT) oligonucleotides (10–40mer) were much smaller when separated using the DNAPac RP column. For instance, the peak area of the 15mer analysed by DNAPac RP was only 43% of the peak area detected when separated by YMC-Triart Bio C18. In addition, YMC-Triart Bio C18 showed reproducible behaviour such as consistent peak areas even after six injections (figure 3). In contrast, DNAPac RP showed a significant decrease in peak areas after only three injections. This makes YMC-Triart C18 an ideal tool for analysis of poly(dT) oligonucleotides.

Ideal choice for poly(dT) oligonucleotides

YMC-Triart Bio C18 columns are the ideal choice for poly(dT) oligonucleotides, due to:

  • High resolution for all sizes of oligonucleotides
  • Higher recoveries of shorter oligonucleotides
  • Consistent and reproducible separation performance
  • Optional bioinert hardware options available.

Digital Edition

Chromatography Today - Buyers' Guide 2022

October 2023

In This Edition Modern & Practical Applications - Accelerating ADC Development with Mass Spectrometry - Implementing High-Resolution Ion Mobility into Peptide Mapping Workflows Chromatogr...

View all digital editions

Events

analytica 2024

Apr 09 2024 Munich, Germany

Korea Lab 2024

Apr 23 2024 Kintex, South Korea

Korea Chem 2024

Apr 23 2024 Seoul, South Korea

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

SETAC Europe

May 05 2024 Seville, Spain

View all events