• Is your Oxygen Gas Analysis Accurate?    

Laboratory Products

Is your Oxygen Gas Analysis Accurate?    

Jan 26 2017

With the Rapidox 2100 zirconia oxygen analyser, sub-ppm measurements to 30% of oxygen gas to can be analysed rapidly and accurately. The robust remote sensor, connected via a cable, can be placed within the heart of the application, providing 24/7 of reliable gas analysis. Gas temperatures of up to 600°C can be analysed by the sensor, with an additional Type K thermocouple providing independent temperature measurements. Auxiliary sensors can be added to suit the application for pressure or dew point.

The Rapidox 2100 is available in a bench mounted configuration, or with a bezel front panel to incorporate the instrument within a rack. An electrochemical oxygen sensor is available as an alternate to zirconia for samples gases which contain VOC’s. Additionally, the Rapidox 2100 can be supplied within a wall mountable, IP65 weatherproof housing. The zirconia sensor can then be positioned remotely up to 26 metres away either in a separate cabinet or as a standalone sensor. For customers requiring seamless integration into their product or process, the Rapidox can also be supplied as an OEM solution.

Standard features on all models include two fully programmable alarm circuits (volt free contacts), programmable analogue outputs (0-10V and 4-20mA), easy calibration (user selectable gases), RS232 / RS485 communications and complete data-logging software.

Ideal applications can include: Additive manufacturing, combustion, glove boxes, inert gas blanketing, manufacturing processes and metal heat treatment facilities.

Latest update: The Rapidox 2100 oxygen gas analyser is undergoing an upgrade and redesign in line with the new Rapidox 1100 model launched last year. The new Rapidox 2100 oxygen gas analyser will be announced in the Summer 2017.

For more information regarding the launch of the redesigned Rapidox 2100, please call our sales team for more information on +44 (0)1480 462142 or email.


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

FORUMESURE

Apr 22 2024 Marrakech, Morroco

Korea Lab 2024

Apr 23 2024 Kintex, South Korea

Korea Chem 2024

Apr 23 2024 Seoul, South Korea

Lab Indonesia

Apr 24 2024 Jakarta, Indonesia

View all events