• Magnum 91 Powerful Temperature System for Reactors Up to 50 Litres

Laboratory Products

Magnum 91 Powerful Temperature System for Reactors Up to 50 Litres

Jun 23 2008

With the ,Magnum 91‘ JULABO offers a powerful highly dynamic temperature control system for demanding external temperature applications, like e.g. temperature control of reactors up to 50 litres. The advantages are rapid heat-up and cool-down within the working temperature range from –91 to +250°C as well as an immediate control of exothermic and endothermic reactions.
The typical applications include control of jacketed reactor vessels, reactor systems, pilot plants and reaction blocks as well as polymerization, polycondensation, distillation and synthesis chemistry. The water-cooled unit offers a heating capacity of 6 kW as well as a cooling capacity of 5 kW at +20°C, 4 kW at 40°C, 2.5 kW at –60°C and 0.6 kW at –80°C.

The circulation pump is electronically adjustable and reaches a flow rate of 24 to 35 l/min resp. a pressure of 0.8 to 2.2 bar. With the intelligent ICC cascade temperature control rapid results with high precision are reached. The temperature stability is between +/-0.05 and +/-0.2°C. For time and temperature depending processes there is an integrated programmer with 6x60 program steps. Additionally the system has a closed tempering circuit, here the advantages are a reduced oxidation and a longer lifetime of the bath fluid – unpleasant odors and vapors do not get outside. Further features are an RS232/RS485 interface, a connection for external Pt100 sensor, an early warning system for temperature limit values as well as a keypad, which is divided into two, with VFD- and LCD display for user input.

The temperature stability is between +/-0.05 and +/-0.2 deg C. For time and temperature depending processes there is an integrated programmer with 6x60 program steps. Additionally the system has a closed tempering circuit, here the advantages are a reduced oxidation and a longer lifetime of the bath fluid - unpleasant odors and vapors do not get outside. Further features are an RS232/RS485 interface, a connection for external Pt100 sensor, an early warning system for temperature limit values as well as a keypad, which is divided into two, with VFD- and LCD display for user input.
Contact Julabo


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

Microbiology Society Annual Conference 2024

Apr 08 2024 Edinburgh 2024

analytica 2024

Apr 09 2024 Munich, Germany

ChemBio Finland 2024

Apr 10 2024 Helsinki, Finland

Analytica Anacon India & IndiaLabExpo

Apr 15 2024 Mumbai, India

Analitika Expo 2024

Apr 16 2024 Moscow, Russia

View all events