• New Portable Analyser Biogas and Syngas ETG MCA 100 Syn P

Portable/Field Testing

New Portable Analyser Biogas and Syngas ETG MCA 100 Syn P

Nov 06 2017

The new portable analyser Biogas and Syngas ETG MCA 100 Syn P is the ideal solution for the measurement and analysis processes for the Biogas to Syngas and burning due to its robustness , accuracy, reliability , and enhance performance.
Unlike other analysers of the same type ETG MCA 100 Syn P performs the analysis of different compounds such as CO, CO2, CH4 NDIR technology with unique optical IR bench . The concentration of O2 by E.C. as well the CnHm, N2 and Calorific value.

The measurement of the concentration of Hydrogen is made ​​highly reliable thanks to the sensor measurement of Hydrogen based on TCD principle of operation ( thermal conductivity ) ; therefore not used for the measurement of Hydrogen , electrochemical cells or other sensors that could interfere with the measurements of Hydrocarbons. Like the versions biogas analyzer MCA 100 Syn- remote- P is standard on PCs and Smartphones (Android , iOS , Windows , etc. .. ), or via a LAN, as well as USB (Wi -Fi as an option).
ETG brings in its laboratories , specific corrections for the measurement of hydrogen into a mixture containing hydrocarbons ( which is precisely the Syngas ) , so as to obtain a measurement as accurate as possible.
Inside there is a suction pump can be activated or not by software, a valve for regulating the flow with the video indication , an in-line filter for the removal of dust , in addition to the optical bench and the electronics required to operate .
The analyzer saves the data in a directory inside the instrument. Csv , dividing and subdividing the log file for the same in different folders named as the current date of analysis; to download the data , the user only needs to insert a memory stick into the mail panel , select the log file in question ( which will be shown with date and time ) and the system will automatically download the data on the pen drive , removing the original file from the internal memory , avoiding the risk of filling the memory.
The analyser is supplied in an impact-resistant case , with degree of protection IP67.

 


Digital Edition

IET 34.2 March 2024

April 2024

Gas Detection - Biogas batch fermentation system for laboratory use with automatic gas analysis in real time Water/Wastewater - Upcycling sensors for sustainable nature management - Prist...

View all digital editions

Events

Ozwater'23

Apr 30 2024 Melbourne, Australia

The Safety & Health Event

Apr 30 2024 Birmingham, UK

ENVEX 2024

May 03 2024 Seoul, South Korea

SETAC Europe

May 05 2024 Seville, Spain

CleanPower 2024

May 06 2024 Minneapolis, MN, USA

View all events