• New Dissolved Gas Analysis (DGA) Monitors for Transformers for Clients Around the World.

Measurement and Testing

New Dissolved Gas Analysis (DGA) Monitors for Transformers for Clients Around the World.

Nov 20 2017

Vaisala is working with power utilities, maintenance providers and asset owners to bring the first commercial units of its OptimusTM DGA Monitor for Transformers online.

As transformer fleets continue to age, the likelihood of faults and failure increases accordingly. Real-time condition monitoring enables asset owners to identify and address potential issues before they result in costly failure, reducing maintenance costs and boosting production and performance.

Vaisala's Optimus monitors transformer oil for the presence of moisture and seven different gases. By tracking real-time levels of hydrogen, carbon monoxide, carbon dioxide, methane, ethane, ethylene and acetylene, it gives asset owners a comprehensive understanding of the condition and health of a transformer, enabling them to make informed proactive maintenance decisions.

While many DGA systems available in the market source equipment and sensors from different manufacturers, the infrared sensor technology used in the Optimus has been developed in-house by Vaisala, benefitting from decades of industrial measurement expertise. This integrated approach, using only Vaisala-manufactured sensors and equipment, ensures optimal performance regardless of operational conditions.

Most significantly, Optimus uses vacuum gas extraction and hermetically sealed and protected optics to completely eliminate the false alarms of the kind that frequently afflict on-site DGA systems. Optimus ensures high quality gas selectivity through its use of vacuum gas extraction, which operates regardless of oil temperature or gas pressure, and by employing spectral scanning to aid selectivity.

The robust and durable device has components and piping that are made of stainless steel and aluminum, features a magnetic gear pump and valves, and relies on no consumables, which would require servicing or replacing. With a practical browser-based user interface, the device has no need for additional software.
"DGA analysis has long been accepted as one of the most effective means of assessing transformer condition," said Teemu Hanninen, Product Manager at Vaisala. "At Vaisala, we recognized that there was room to improve the reliability, usability and lifetime costs of the existing devices, and we decided to take on the challenge. With its proven durability and sensors protected from contamination, Optimus has shown that it can deliver reliable and accurate data."


Digital Edition

PIN 25.2 Apr/May

May 2024

Safety - Carbon monoxide toxic and flammable gas detection Analytical Instrumentation - Density: A fundamental parameter at critical stages within the petroleum sector - Advancements and...

View all digital editions

Events

IOSC 2024

May 13 2024 New Orleans, LA, USA

OGU 2024

May 14 2024 Tashkent, Uzbekistan

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

REGATEC 2024

May 15 2024 Lund, Sweden

CO2 Capture, Storage & Reuse

May 15 2024 Copenhagen, Denmark

View all events