• Aura® Elite - The Standard in Ductless Hoods

Laboratory Products

Aura® Elite - The Standard in Ductless Hoods

Aug 25 2014

Aura® Elite ductless fume hoods offer superior protection from fumes, vapors and particulate. Unlike traditional fume hoods there are no installation costs or ductwork needed.

Aura® Elite ductless fume hoods are fitted with the EverSafe™ III advanced microprocessor safety controller. EverSafe™ III features a LCD display of face velocity to assure users they are working within OSHA requirements. Sophisticated controls determine chemical breakthrough based on the type of solvents used within the hood. Visual and audible alarms alert operators if the airflow is at an unsafe level or if filters are approaching saturation, allowing sufficient time to replace filters. EverSafe™ III maintains fume hood face velocity by taking constant measurements at the opening and adjusting airflow to ensure compliance to user preset values.

Aura® Elite ductless fume hoods have a wide selection of gas phase and mechanical filtration media options. Mystaire® gas phase filtration utilises a broad range of charcoal based, coconut shell activated carbon and chemisorptive carbon for special applications to ensure containment. Application validation and proper filter selection are critical to ensuring operator safety and fume hood performance.

Features:

  • EverSafe™ III touch screen controller constantly monitors fume hood performance with audible and visible alarms;
  • Large icon display for simple touch control of hood functions;
  • Variable airflow control with automatic airflow sensor calibration — no service technician required;
  • Solid state gas detection with three level sensitivity selection;
  • Temperature and humidity sensor to monitor filter performance;
  • Fiberglass spill tray;
  • LCD readout of airflow in linear feet per minute or meters per second;
  • Built in filter and application validation by chemical classification;
  • Conforms to UL, CSA and CE;
  • Lab event time-count down and elapsed time;
  • 110/220 V AC;
  • Filter performance verified by Fourier Transform Infrared Spectroscopy analysis (FTIR);
  • ASHRAE 110-1995 certified;
  • Meets applicable OSHA and ANSI standards; and
  • Full width sash openings; 30", 42", 54".

Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

SETAC Europe

May 05 2024 Seville, Spain

InformEx Zone at CPhl North America

May 07 2024 Pennsylvania, PA, USA

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

ChemUK 2024

May 15 2024 Birmingham, UK

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

View all events