• New Reveleris® iES Flash Chromatography System Simplifying Your Purification Challenges 

Laboratory Products

New Reveleris® iES Flash Chromatography System Simplifying Your Purification Challenges 

Sep 08 2010

The award winning Reveleris® flash purification system product range is now expanded with our latest model. The NEW Reveleris® iES flash chromatography system is specifically designed to enable an increase in the speed of isolation of new molecular entities and natural product extracts.
Capable of low mg limits of collection enabled by the unique patent-pending RevealX™ technology, you can be sure of high yield recoveries of both chromophores and non-chromophores. The system also offers enhanced solvent management for added safety, security and rapid solvent switching.
Also included as standard on the Reveleris® iES model is our new Navigator software which enables you to take data from TLC or HPLC scouting runs to assist in method optimisation. The software’s unique patent-pending advanced algorithm then calculates the best conditions for either speed or purity. It can work with 2 or 3 component TLC or RP HPLC data.
The patent-pending RevealX™ technology used on all of the Reveleris® range, synchronizes light scattering (ELS) and dual UV detection to overcome the limitations of traditional UV based flash which only detects chromophoric components - missing impurities or potential compounds of interest. The Reveleris® multiple detector signals identify and collect more compounds, including those that are non-chromophoric, while providing real-time indication of a mixture’s relative mass balance. ELS-triggered purifications provide higher quality information for ongoing analyses and assays, giving fewer false positives and false negatives.
The instrument has binary gradient functionality with four solvent selection, extended reservoir capacity and because of the ELS detection, the ability to use UV absorbing solvents.
Control of all instrument parameters is from a single large adjustable 30cm touch screen which swings out of the way, when required, for safe and easy access to solvent reservoirs.
Safety is built into the design with vapor sensors that detect any leaks and shut the instrument down, solvent and waste level sensors so that there is no spillage of flammable solvents and also so that your valuable samples are not lost should you run out of solvent during a run.
The compact single case instrument contains both UV detectors, the ELS detector, fraction collector trays, all pumps and valving for a minimal bench footprint. There is no need for any difficult external connections or gas supplies. Just plug the instrument into a suitable power socket and it is ready to start detecting and collecting fractions.
New Reveleris® RFID tagged cartridges streamline instrument operation to save time and reduce costs. These cartridges withstand pressures up to 200psi and have tight particle size distribution to resolve and recover more. Their high loading capacity means that in many cases smaller cartridges can be used which cost less, use less solvent and run faster. The RFID tags also automatically populate major instrument method parameters for fast, easy, optimised separations.
You can request further information on this revolutionary system online or contact us using the details below.

Email: discoverysciences.UK@grace.com

Telephone: +44 (0)1524 734451

Fax: +44 (0)1524 733599

WebSite: www.discoverysciences.com


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

SETAC Europe

May 05 2024 Seville, Spain

InformEx Zone at CPhl North America

May 07 2024 Pennsylvania, PA, USA

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

ChemUK 2024

May 15 2024 Birmingham, UK

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

View all events