• The AquaLog The world’s first simultaneous fluorescence and absorbance Spectrophotometer for CDOM measurements

Mass Spectrometry & Spectroscopy

The AquaLog The world’s first simultaneous fluorescence and absorbance Spectrophotometer for CDOM measurements

Mar 05 2014

The Aqualog is a fluorescence instrument for rapidly measuring and identifying CDOM in water. The measurement is based on fluorescence excitation-emission matrices (EEMS) corrected for all instrumental factors. These corrections require an absorbance measurement to also be performed on the water sample.

Key features

•    The only instrument to measure both fluorescence and absorbance spectra in a single instrument for water quality analysis
•    Up to 100 fold faster data acquisition rates than any other benchtop fluorometer
•    Table-top instrument based on a CCD detector for fast simultaneous readout of the entire emission spectrum
•    Software routines automatically correct data for inner filter effects, Rayleigh line scattering, water Raman scattering, normalize the intensity scale, and export data for analysis in industry standard 3rd party packages.

Its main benefits are:

-    Table-top instrument based on a TE cooled CCD detector for fast simultaneous readout of the entire emission spectrum, means less analysis time or more samples
-    Analysis of samples with orders of magnitude variation in concentration without the need for tedious dilutions
-    Eliminating sample aging, bleaching and dilution issues as experimental variables. AqualogTM measures fully corrected EEMs in seconds. Rapid acquisition reduces bleaching compared to ‘scanning’ instruments that require up to 100 times longer data collection, exposing the sample to damaging UV wavelengths the whole time.
-    The instrument is fully automated.

-    Software: The Aqualog software automatically:
    o    masks the Rayleigh scatter lines
    o    normalizes to traceable intensity standards (Quinine Sulfate or Raman Scattering)
    o    offers 2-dimensional profiling of the ‘integrated’ excitation and emission spectra from EEMs
    o    corrects and batch exports the data for multivariate analysis using the industry standard Parallel Factor Analysis (PARAFAC) method, reducing data analysis time by a factor of ten
-    Corrected UV-VIS absorbance detection path for stability and accuracy
-    Double grating excitation monochromator for superior stray light rejection
-    Matching bandpass for absorbance and fluorescence spectra
-    The optics: We only use aberration-corrected mirrors (no lenses) to increase the wavelength range, for you cannot get good anti-reflection coatings from 200 nm up through 850 nm or above. Lenses also suffer from chromatic aberrations, meaning different wavelengths focus at different depths in the samples, and consequently you lose sensitivity. 
-    Gratings: HORIBA, previously known as Jobin Yvon, has been designing and making ruled and holographic gratings for over 50 years. We use plane-ruled gratings in our instruments as opposed to cheaper holographic ones, because ruled gratings are much less dependent on polarization effects.
-    The excitation source is a 150 W ozone-free xenon lamp. It is mounted vertically to prevent sagging and keep the illumination of the sample optimal.
-    A photodiode reference detector monitors the intensity as a function of time and wavelength to correct for any change in output due age or wavelength, and ensure more repetitive measurements. This reference detector enables to correct both absorbance and fluorescence detector signals.

To contact us email at info-sci.fr@horiba.com or visit us at www.horiba.com


Digital Edition

ILM 49.5 July

July 2024

Chromatography Articles - Understanding PFAS: Analysis and Implications Mass Spectrometry & Spectroscopy Articles - MS detection of Alzheimer’s blood-based biomarkers LIMS - Essent...

View all digital editions

Events

ADLM 2024

Jul 28 2024 San Diego, CA USA

InaLab 2024

Jul 30 2024 Jakarta, Indonesia

Miconex

Jul 31 2024 Chengdu, China

ACS National Meeting - Fall 2024

Aug 18 2024 Denver, CO, USA

EMC2024

Aug 25 2024 Copenhagen, Denmark

View all events