New Triple Quadrupole Mass Spectrometer Achieves Ultra-Fast, Accurate Analysis

May 30 2012

The number of chemical substances that can harm the environment continues to increase. Chemists need to measure these contaminants quickly and accurately, but sample pretreatment and interference from complex matrices can be problematic. Shimadzu’s new GCMS-TQ8030 triple quadrupole gas chromatograph mass spectrometer offers a solution to these challenges along with the speed, accuracy and ease-of-operation scientists want.

With Shimadzu’s high-efficiency, proprietary ion source the GCMS-TQ8030 achieves the highest sensitivity specification in its class for multiple reaction monitoring (MRM) measurements by GC/MS/MS, as well as for scan and SIM measurements by GC/MS. The instrument’s high-sensitivity analysis allows a wide variety of measurement modes, including MRM, scan, combination scan/MRM, neutral loss scan and others

The GCMS-TQ8030 features Shimadzu’s UFsweeper® technology, which minimises collision cell length and provides high-CID efficiency and high ion transport speed. UFsweeper accelerates ions out of the collision cell by forming a pseudo-potential surface, preventing any drop in signal intensity or cross talk, even at ultra-fast measurement speeds.

The system comes equipped with Advanced Scanning Speed Protocol (ASSP™), an internal protocol that optimises ion transmission parameters during the scan acquisition process. Scan speeds of up to 20,000μ/sec and high-speed multiple reaction monitoring (MRM) measurements (600 transitions/sec) facilitated by UFsweeper make high-speed MRM acquisition possible.

The GCMS-TQ8030 comes equipped with an Ecology mode that reduces the power consumed in analysis standby mode by 36 percent. Ecology mode eliminates unnecessary power consumption by the GC, MS and PC, and it also decreases the consumption of carrier gas. When used over one year of operation, Ecology mode reduces power consumption by 26 percent and carbon dioxide emissions by about 1.1 tons.
 


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

FORUMESURE

Apr 22 2024 Marrakech, Morroco

Korea Lab 2024

Apr 23 2024 Kintex, South Korea

Korea Chem 2024

Apr 23 2024 Seoul, South Korea

Lab Indonesia

Apr 24 2024 Jakarta, Indonesia

View all events