Chromatography

Headspace Autosampler Range Expanded to Support High-Temperature Applications

Oct 03 2016 Read 843 Times

HTA is proud to announce the extension of its headspace autosampler solutions: after HT2000H and HT2100H, the HT2000HT is being introduced.

 

The HT2000HT features an upper sample heating temperature of 300°C: it enables the execution of high-temperature headspace applications in a syringe-based system, without the constraints and limitations induced by valve&loop systems.

 

The HT2000HT incubation oven offers a 3-position heating and shaking chamber, allowing the simultaneous incubation of multiple samples.

 

The incubation temperature can be set between 40° and 300°C to accommodate the widest range of applications: the system can handle standard headspace applications (that require temperatures lower than 150°C), whilst still being well-suited to special high-temperature applications that include analysis of high-boiling compounds and polymers.

 

The HT2000HT features all the outstanding characteristics of HT2000H: compactness (near to zero requirement for bench space); universal compatibility (it can be interfaced with almost any gas chromatograph and it can serve both the front and rear injector in most supported GCs); ease to use by means of the full-colour touch screen interface; the lowest cost of ownership (no need for carrier gas); innovative technologies as vial leakage check and system integrity test.

 

The key feature that distinguishes HT2000HT within HTA headspace solutions is the support of temperatures up to 300°C, making it the ideal solution for polymer analysis, as well as quality control of chemical product materials and for heat-induced degradation studies.

Read comments0

Do you like or dislike what you have read? Why not post a comment to tell others / the manufacturer and our Editor what you think. To leave comments please complete the form below. Providing the content is approved, your comment will be on screen in less than 24 hours. Leaving comments on product information and articles can assist with future editorial and article content. Post questions, thoughts or simply whether you like the content.


Digital Edition

Lab Asia March / April 2018

April 2018

In this issue... Chromatography - Biphenylpropyl Modified Silica - New Application Book Offers Expertise in GPC Analysis - Same Separation, Speedier Solution - Advanced Laboratory Manageme...

View all digital editions

Events

CISILE 2018

Apr 21 2018 Beijing, China

Making Pharmaceuticals UK

Apr 24 2018 Ricoh Arena, Coventry, UK

Analytika Expo 2018

Apr 24 2018 Moscow, Russia

Chemspec India 2018

Apr 25 2018 Mumbai, India

Analytica Anacon India & IndiaLabExpo

Apr 25 2018 Mumbai, India

View all events