New Bioinert (U)HPLC Columns for High Accuracy Analysis
YMC-Accura Triart columns are fully bioinert thanks to their surface coating and are ideally used with a bioinert system.
Significantly increased peak heights and areas are obtained using a YMC-Accura Bio C18 column for the challenging analysis of phosphorothioate oligonucleotides.
Significantly increased peak heights and areas are obtained using a YMC-Accura Bio C18 column for the challenging analysis of phosphorothioate oligonucleotides.

Columns

New Bioinert (U)HPLC Columns for High Accuracy Analysis

25 Jul, 2022

Published over 3 years ago. See the latest and most current information on Columns.

Several substances are able to interact with more common ‘inert’ column hardware materials such as stainless steel or titanium. Critical substances in particular are oligonucleotides or nucleotides. Further sensitive substances are various peptides and proteins as well as coordinating small molecules. The adsorption on metallic surfaces typically leads to peak tailing, loss of recovery and sample carry over. This behaviour can especially be seen when a new column is used without any conditioning before the actual analysis.

For these challenging substances YMC is offering different bioinert hardware options for their YMC-Triart columns. The newly released YMC-Accura Triart (U)HPLC columns are characterised by a bioinert surface coating of the column body and frit. The coating is less hydrophobic compared to the PEEK lining used in the YMC-Triart metal-free (U)HPLC columns. These 2 options allow for the optimum hardware for analyses of any sensitive compound. Further, YMC-Accura columns are ready to use without any preconditioning, which is usually required for analysis of sensitive substances using standard columns.

Due to its organic/inorganic hybrid silica base material, YMC-Triart stationary phases contain no metal impurities. In combination with the bioinert YMC-Accura column hardware, YMC-Triart columns show excellent peak shapes for sensitive compounds, prevent carry over and ensure complete recovery. They are especially ideal for the use in highly sensitive LC/MS analyses.

All 8 YMC-Triart phases are available in inert YMC-Accura columns - with 1.9 µm for UHPLC or 3 or 5 µm for HPLC. The preferred choices for e.g. oligonucleotide or peptide separations are YMC-Triart C18 or YMC-Triart C8 with a pore size of 120 Å. YMC-Triart Bio C18 or Bio C4 with a larger pore of 300 Å are particularly suitable for more hydrophobic oligonucleotides and larger peptides or proteins. Other column options are the polar YMC-Triart Diol-HILIC, the aromatic YMC-Triart Phenyl and PFP and the extremely hydrophobic YMC-Triart C18 ExRS.

Latest News

ILM Guide 2026/27

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Envirotech Online
Mobile platform for real-time water quality monitoring, calibration and data management
Explore more Arrow
Pollution Solutions Online
DNV introduces new framework for measuring onboard carbon capture performance
Explore more Arrow
Petro Online
New test method ASTM D8606 has been officially released
Explore more Arrow
Chromatography Today
Affordable liquid chromatography solvent delivery pump
Explore more Arrow