Laboratory Products

  • Reproducible measuring results for particle shape and size in a few minutes!
    Particle Sizer ANALYSETTE 28 ImageSizer for dry and wet measurement of particle shape and size
  • Particle Sizer ANALYSETTE 28 ImageSizer for dry measurement of powders and bulk solids
  • Uncomplicated single image analysis via the FRITSCH Cloud and Gallery

Reproducible measuring results for particle shape and size in a few minutes!

Apr 03 2019 Read 247 Times

Experience the Particle Sizer ANALYSETTE 28 ImageSizer live at POWTECH 2019 • Hall 2 • Booth 2-227. It is ideal for all applications that require accurate and reproducible measuring results for both particle shape and size of powders and suspensions in a measuring range of 20 µm - 20 mm.

Dynamic Image Analysis instead of a microscope

With the principle of Dynamic Image Analysis, the FRITSCH ANALYSETTE 28 ImageSizer offers all benefits of an analysis via microscope, but records due to the fully automatic process with up to 75 images per second a considerably higher number of particles. Instead of just one image, any freely definable number of images can be recorded and evaluated. You can see the result of the analysis directly without any complicated evaluation just like with a microscope. Your advantage: Faster, representative results and higher precision in evaluation.

Absolutely reliable quality control in 3 simple steps

Ensure higher quality, reduced rejects and lower costs with the Particle Sizer ANALYSETTE 28 ImageSizer: fast, safe and uncomplicated by measuring particle shape and size. With short measuring times of less than 5 minutes and reliable reproducibility thanks to pixel-accurate evaluation. For always consistent results. Just add sample, start measurement and read evaluation.

Fast alternative to sieving

If you conduct many and frequent sieve analyses, the ANALYSETTE 28 ImageSizer is the ideal, time-saving alternative completely without weighing, assembling of a sieve stack and time-consuming cleaning. And with substantially reduced follow-up costs, as there is no need to calibrate or purchase new sieves. And additionally, you receive besides the particle size distribution, also valuable information about the particle shape.

Choose according to you needs.

Efficient dry measurement of powders and bulk solids
The ANALYSETTE 28 ImageSizer is the ideal Particle Sizer for fast analysis of particle shape and size of dry, free-flowing materials in a measuring range of 20 µm – 20 mm. Via the optical analysis of the particle shape and particle size, you can identify damaged particles, contaminates, agglomerates or oversized and undersized particles accurately and fast and view them completely uncomplicated in single images.

Easy wet measurement of suspensions and emulsions
The ANALYSETTE 28 ImageSizer is in combination with the corresponding wet dispersion unit ideal for measurement of particle shape and size of suspensions and emulsions in a measuring range of 20 µm – 2.8 mm.

Wet dispersion is particularly suitable for fine particles, poorly flowing, fine-agglomerating or sticky materials, which do not react in water or other liquids.

And if your measurement tasks change, the ANALYSETTE 28 ImageSizer can be retrofitted and adapted at any time.

State-of-the-art, simple and fast evaluation via FRITSCH Cloud and Gallery
The evaluation of the measuring results is uniquely simple with the ANALYSETTE 28 ImageSizer. The evaluation software ISS displays each recorded particle clearly as a data point in the immediately available FRITSCH Cloud as well as in the FRITSCH Gallery. You freely choose which statement is of interest to you: for example the Sphericity in regards to the Minimum Feret Diameter, the aspect ratio, applied on the porosity, or the convexity as a function of the particle Cross Section. Or display the particle size distribution as a cumulative curve, as a bar chart or in a table form.

Test the FRITSCH Particle Sizers!
Send us your sample for an individual sample measurement – we will send you a detailed analysis protocol. Compare for yourself

Click here for up-to-date information on FRITSCH high-tech particle technology – from Dynamic Image Analysis to Static Light Scattering.

Reader comments

Do you like or dislike what you have read? Why not post a comment to tell others / the manufacturer and our Editor what you think. To leave comments please complete the form below. Providing the content is approved, your comment will be on screen in less than 24 hours. Leaving comments on product information and articles can assist with future editorial and article content. Post questions, thoughts or simply whether you like the content.

Post a Comment




Digital Edition

International Labmate July 2019

July 2019

In This Edition Mass Spectrometry & Spectroscopy - 67th ASMS Conference on Mass Spectrometry and Allied Topics - Modular MS Bench System with Integrated Gas Supply for Sciex LC-MS/MS Unveile...

View all digital editions

Events

AACC Annual Meeting & Clinical Lab Expo

Aug 04 2019 Anaheim, CA, USA

M&M 2019

Aug 04 2019 Portland, OR, USA

DXC 2019

Aug 05 2019 Lombard, IL, USA

ACS National Meeting & Expo, Fall 2019

Aug 25 2019 San Diego, CA, USA

Microscopy Conference 2019

Sep 01 2019 Berlin, Germany

View all events