• Blood Temp 10 Temperature Breach Indicator - Improving critical decision making for blood bag reissue
    Simply adhere this simple device to a blood bag and Blood Temp 10 will immediate monitor for temperature breaches above +10 Deg C
  • Accurate core temperature monitoring at the touch of a button, reducing reliance on manual temperature and 30 minute readings

Blood

Blood Temp 10 Temperature Breach Indicator - Improving critical decision making for blood bag reissue

Blood re-issue compliance at the touch of a button!                                                       

Helapet are pleased to offer the Blood Temp 10 breach indicator as an auditable and convenient alternative for insitutions who rely on the “30 minute rule” for blood bag reissue.

Standard regulatory compliance requires blood to be maintained between +1°C and +10°C for each blood bag to be considered for reissue. The 30 minute rule provides simple guidance for allowing un-used blood bags to be returned to storage, but opens up the risk of needless discarding of bags which may not have breached the +10°C threshold.

Blood Temp 10 is designed to offer a simple, easy-to-use and accurate solution by monitoring the core temperature of the blood bag and irreversibly highlighting any breaches above +10°C by changing colour of the indicator window. If the indicator window remains white even after 30 minutes, the blood may be safely reissued potentially saving significant blood losses.

Activated with no pre-conditioning required by simply pressing the blister button, Blood Temp 10 will immediately begin monitoring the bag core temperature, providing instant and accurate information for front line users. Securely applied using an adhesive backing, Blood Temp 10 consistently safeguards against any unnecessary breaches, removing the need to manually take time or temperature readings.

To see how Blood Temp 10 can help benefit you department, simply call Helapet on our UK freephone 0800 0328 428 or email sales@helapet.co.uk to request your free samples.


Digital Edition

ILM 50.3 April 2025

May 2025

Chromatography Articles - Optimising two-step purification: Key considerations for sample pump setups Mass Spectrometry & Spectroscopy Articles - Detecting pharmaceuticals and their transf...

View all digital editions

Events

InformEx Zone at CPhl North America

May 20 2025 Philadelphia, PA, USA

ChemUK 2025

May 21 2025 Birmingham, UK

Future Labs Live Basel 2025

May 27 2025 Basel, Switzerland

ASMS Conference

Jun 01 2025 Baltimore, MD, USA

Chemspec Europe 2025

Jun 04 2025 Koeln, Germany

View all events