• High Temperature GC Column Line Expanding

Chromatography

High Temperature GC Column Line Expanding

Nov 19 2009

Phenomenex, Inc announced the expansion of its successful Zebron Inferno high temperature GC column line, adding two new mid-polarity columns. The new ZB-XLB-HT and ZB-35HT are the first mid-polarity columns
that can withstand temperatures up to 400°C, enabling analyses of compounds with high molecular weights and boiling points. The Zebron Inferno non-metal columns are stable at high temperatures due to proprietary
coating and binding technologies, providing long lifetime, low bleed and low activity. They are ideal for analyses in environmental, food and beverage, pharmaceutical, toxicology and biofuels applications.

Standard fused-silica columns are not engineered to withstand temperatures above 380°C and their polyimide coating begins to degrade, eventually becoming brittle and inflexible. The Phenomenex Inferno columns
are specially designed for high-temperature analysis, with more rugged stationary phases and coating.

The ZB-XLB-HT Inferno column is stable up to 400°C and provides unique selectivity for confirmational analyses. This MS-certified column offers low activity and good peak shape for acidic and basic samples. The ZBXLB-
HT proprietary phase is ideal for polychlorinated biphenyls (PCBs), pesticides, herbicides and many EPA methods. The ZB- 35HT is a 35%-phenyl-65%-dimethylpolysiloxane intermediate-polarity column that is stable up
to 400°C, enabling high molecular weight analysis. It is particularly well suited for trace analysis with bleed-sensitive detectors. Applications include semi-volatile compounds, pesticides, drugs of abuse, pharmaceuticals, steroids and many EPA methods.

“Our successful Zebron columns were the first non-metal columns to provide stability at very high temperatures,” commented Ngoc Nguyen, Brand Manager for Phenomenex. “The increased column stability can be beneficial even for routine temperature ramps above 320°C, which can cause some GC columns to become brittle and produce high bleed.”


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

ChemUK 2024

May 15 2024 Birmingham, UK

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

Discovery Europe 2024

May 22 2024 Basel, Switzerland

View all events