• Ensuring Your Microtitre Plates are Cold Enough on Ice

Laboratory Products

Ensuring Your Microtitre Plates are Cold Enough on Ice

Apr 15 2011

Used as an interface between a microplate and crushed ice, the BioCision CoolSink thermo-conductive plate holder provides fast equilibration of all wells to below 4ºC and excellent well-to-well temperature uniformity.
Many experimental and clinical applications require low temperature control for culture plates. However, a new Application Note published in BioTechniques demonstrates that although it is commonly assumed that a plate in direct contact with crushed ice will rapidly equilibrate below 4ºC, this is not the case. In fact, the unstable nature of crushed ice and insulating air gaps between plate and ice mean that uniform and reproducible cooling are very difficult to achieve. Brian Schryver and Rolf Ehrhardt, MD, PhD found that for 96-well plates placed directly onto crushed ice, the average well temperature was 6.7ºC, significantly above the critical threshold of 4ºC. Furthermore, the well-to-well temperature variation was as wide as 3ºC.

By contrast, placing a plate on BioCision’s thermo-conductive CoolSink and then putting the assembly on ice brings all wells to or below 4oC and the well-towell temperature range was more uniform. The addition of an aqueous conductive medium (ACM) to replace air between the plate and CoolSink surface further enhanced results, with even faster equilibration to a final temperature of 3.3ºC, and less than 1ºC variation between wells.
According to co-author Brian Schryver, BioCision Vice President, Research and Product Development: “CoolSink’s precision-engineered “direct contact” stage design eliminates the insulating air gap typically found between plate wells and the resting surface. The module’s excellent thermo-conductivity, due to its patented novel alloy construction, gives fast equilibration to below 4ºC, and using an ACM produces near identical well temperatures. This set-up provides a very simple way for researchers to ensure that all their samples are treated uniformly with no ‘plate edge effect’.

CoolSink is an ideal tool for increasing the reproducibility of results in a variety of applications, such as cell-based assays, ELISA, FACS staining and analysis, migration or adhesion studies, temperature shift assays or any work with temperature-sensitive biomarkers.”


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

SETAC Europe

May 05 2024 Seville, Spain

InformEx Zone at CPhl North America

May 07 2024 Pennsylvania, PA, USA

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

ChemUK 2024

May 15 2024 Birmingham, UK

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

View all events