If it's reliable and verifiable - pH measurement you need, look no further than Endress and Hauser Ltd's Memosens digital pH sensor. It allows important process data to be saved directly in the sensor, guaranteeing interference-free measuring signals while also simplifying process measuring technology. But that's not all: reach for the Memocheck Plus qualification tool and it will verify this data transmission independently of the sensor, so you can be absolutely sure of your readings. With five plug-in heads (each traceable back to production via a serial number) each simulating a particular sensor status, Memocheck makes measurement integrity watertight.

Memosens eliminates the problems of moisture ingress, leakages and corrosion. Its inductive, plug-in connection and bayonet lock offer complete galvanic isolation. Inside, the sensor's unique capabilities are enabled by its integrated circuit board, which offers a wealth of possibilities: manufacturing data, current sensor properties and sensor history can all be recorded and used as a basis for predictive maintenance. It also stores calibration data, along with other important information such as overall time in operation, and maximum/minimum pH value and temperature.

Memosens sensors can be pre-calibrated under optimum conditions in the laboratory and then simply replaced in the measuring point - eliminating the problems associated with difficult-to-access measuring points! The sensors identify themselves within the application - each measuring point recognises its individual sensor, providing a significant reduction in downtime. What's more, sensors that once had to be thrown away can now be checked and regenerated, e.g. by cleaning in the laboratory, so that sensor lifetime is considerably increased. And, thanks to the pre-calibration, work in hazardous areas is minimal.

The Memosens system is the complete package: it even offers solutions right through to problem-solving and troubleshooting. The Memocheck CYP02D service tool provides a quick and easy test of wiring and installation. It can also be used on-site to troubleshoot a system which has already been commissioned, to establish possible causes of error. By using the complete family the Memosens digital pH sensor, the Memocheck Plus CYP01D qualification tool and the Memocheck CYP02D service tool - you'll have peace of mind of knowing that all your measuring points are working at optimum efficiency and productivity.

Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

Microbiology Society Annual Conference 2024

Apr 08 2024 Edinburgh 2024

analytica 2024

Apr 09 2024 Munich, Germany

ChemBio Finland 2024

Apr 10 2024 Helsinki, Finland

Analytica Anacon India & IndiaLabExpo

Apr 15 2024 Mumbai, India

Analitika Expo 2024

Apr 16 2024 Moscow, Russia

View all events