Single Cell Gene Expression Analysis Using A Nanofluidic Platform

Feb 25 2010

A technical poster is available from Fluidigm Europe that demonstrates a new approach, which when used in combination with Fluidigm’s BioMark™ real-time PCR system, provides a simple, inexpensive and reproducible solution to single cell gene expression.

The authors of the poster demonstrate the use of the Fluidigm 48.48 Dynamic Array™ integrated fluidic circuit (IFC), as well as a technique known as specific target amplification (STA). Each 48.48 Dynamic Array
is shown to systematically combine samples and assays into 2,304 real-time qPCR reactions, of final reaction volumes of 6.75 nanolitres. Experimental results are shown using FACS-sorted single cells from
a human colorectal carcinoma cell line (HCT 116).

Using the Fluidigm 48.48 Dynamic Array IFC, the researchers were able to conduct gene expression studies from single cells, with excellent sensitivity. While significant differences in expression levels of
the same genes across multiple (supposedly identical) single cells was observed, the BioMark / 48.48 Dynamic Array platform is shown to produce extremely consistent results when identical amounts of actual transcript were tested.

The Fluidigm 48.48 Dynamic Array IFC provides a highly efficient solution for single cell gene expression quantification studies using off-the-shelf TaqMan® PCR assays and reagents. The key to 48.48 Dynamic Array is the matrix of channels, chambers, and valves that do the work of assembling assays. Using the product scientists can enjoy the same qPCR data quality and experiment flexibility that they are currently receiving from a 384-well microplate system while increasing throughput 24X. To run an experiment - 48 samples and 48 assays are loaded into the inlets of the Dynamic Array input frame and pressure loaded into 2,304 reaction chambers. Using this simple approach scientists are able to test 48 genes against 48 samples in a single run. The savings in time and effort add up rapidly. With dynamic arrays, genetic researchers can advance their
research much more easily and affordably, and they can do so while using gold-standard TaqMan® assays.


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

SETAC Europe

May 05 2024 Seville, Spain

InformEx Zone at CPhl North America

May 07 2024 Pennsylvania, PA, USA

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

ChemUK 2024

May 15 2024 Birmingham, UK

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

View all events