Identification and confirmation of substances in research and routine analysis by hyphenation of HPTLC with MS 

Oct 07 2015

CAMAG, a leading manufacturer of HPTLC equipment, recently announced the worldwide availability of the new CAMAG TLC-MS Interface 2, the second generation of its module for the pioneering concept of hyphenating HPTLC with mass spectrometry. While the visual appearance remains virtually unchanged, the CAMAG TLC-MS Interface 2 features a modified elution head and an easily accessible, exchangeable filter, arranged in front of the valve. Cleaning is facilitated as compared to the previous version, making it highly efficient. By pushing a button, the elution path is cleaned of matrix particles with compressed air, increasing the lifetime of the filter and preventing the system from becoming blocked. These filters can be easily replaced without any modification to the elution head. 

With the new CAMAG TLC-MS Interface 2, plate positioning is significantly simplified: together with the positioning scale and the adjustable plate-stopper, the integrated crosshair laser enables accurate and reproducible positioning of the plate. Alternatively the coordinates determined by the CAMAG TLC Visualizer or the CAMAG TLC Scanner can be used to precisely position the HPTLC plate. 

The CAMAG TLC-MS Interface 2 can be installed plug & play with any LC-MS system without adjustments or mass spectrometer modifications. Depending on the MS system, a substance can be identified within a minute via its mass spectrum, or for an unknown substance zone, the respective sum formula can be obtained. Furthermore, interesting zones can be eluted into vials for further investigations with, e.g, NMR, (ATR-)FTIR, ESI-MS, and MALDI-MS. 

Please click here for further information.


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

SETAC Europe

May 05 2024 Seville, Spain

InformEx Zone at CPhl North America

May 07 2024 Pennsylvania, PA, USA

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

ChemUK 2024

May 15 2024 Birmingham, UK

View all events