Cnsolution™ Cyanide Analyzer - Automated Cyanide Analysis

Nov 12 2008

The CNSolution Cyanide Analyzer is a compact modular system for flow injection analysis of cyanide in drinking water and wastewater samples from mining, metal plating, and other industrial operations.

The modular design allows the CNSolution to be configured to analyse free cyanide, available cyanide, weak acid dissociable (WAD) cyanide, cyanide amenable to chlorination (CATC), and total cyanide.

Cyanide analysis can be performed using the analytical technique and method appropriate for a particular application and regulatory requirements. Cyanide analysis methods employ different techniques for breaking down metal-cyanide complexes. Older methods typically involve a
preliminary 2 hour acid distillation step.

A drawback of acid distillation is that accurate determination of cyanide is not possible if sulfur-species are present in the sample.
Newer methods eliminate the acid distillation step, utilising a ligand-exchange sample pretreatment step or an in-line UV digestion step to breakdown cyanide complexes for analysis.
These non-distillation techniques allow accurate cyanide determination in the presence of sulfur-species interferences, andprovide results in minutes versus hours required when a method with an acid distillation step is used.
The CNSolution measures free, available and WAD cyanide using a ligand-exchange, gas diffusion separation technique with amperometric detection. The CNSolution measures total cyanide using an in-line UV digestion, gas diffusion separation technique with amperometric detection.
In cases where a laboratory must use a regulatory method involving acid distillation and colorimetric analysis, the CNSolution can be equipped with a photometric detector. USEPA Method OIA-1677 and ASTM Method
6888-04 for available/WAD cyanide, and USEPA Method 335.4 and ISO-14403:2002 for total cyanide are some of the analytical methods
that can be performed using the CNSolution cyanide analyzer.

Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

ChemUK 2024

May 15 2024 Birmingham, UK

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

Discovery Europe 2024

May 22 2024 Basel, Switzerland

View all events