• Captair Flex: safety, performance and energy savings

Laboratory Products

Captair Flex: safety, performance and energy savings

Aug 26 2014

Designed by Erlab®, Captair® Flex® non ducted mobile filtration fume hoods ensures optimal operator protection by being able to adapt itself to the handling of liquid and solid toxic chemicals, separated or combined, in laboratories and clean rooms.

The Captair Flex range can be configured to the protection needs of laboratories. By combining molecular and particulate HEPA H14 filtration technologies, the Flex technology allows the user to do a very large variety of : liquid handlings, such as dilutions, titrations, extractions, transfers ; solid handlings such as sieving, grindings, weighings, formulations, compressions and to combine liquids and solids for dissolutions, filtrations and extractions. This new range can also be adapted to the lab environment such as cleanrooms up to class ISO 5 classification.

Filtration technologies used in the design of captair® Flex® non ducted filtration fume hoods also enable to protect the environment : Since no ductwork is required, the direct discharge of pollutants into the atmosphere is eliminated. It also reduces carbon footprint as it does not generate any pollution linked to energy production unlike a traditional ducted fume hood. The installation is quick and easy. There is no need for a ductwork linked to an air supply / air extraction system, in comparison to traditional ducted systems. The installation can be done at any time, without complex forward planning. Users can also benefit from an immediately available unit, easy to relocate without disturbing room air balance.

This ductwork air balance, essential to the proper operation of a traditional ducted fume hood however is also the source of very important energy consumption. Captair® Flex® filtered enclosures do not generate any energy costs associated with the use of expensive extraction systems or conditioned air supplies. Operational costs can, by consequence, remain at a minimum even when taking into account filters changes.

The compliance of the captair® Flex® range with the 2009 AFNOR NF X 15-211, the major standard related to ductless filtering fume hoods, insures users real performance criteria with regards to : Filtration efficiency (the emission concentration at the filter exhaust must be lower than 1% of the handled product TLV), containment (the maximal concentration of of SF6 tracer gas at the measuring points as described in the standard procedure is 0.1 ppm) and air face velocity (the air face velocity at any point of the front openings must be between 0.4 and 0.6 m/s).

Associated with the Erlab Safety Program (ESP), an exclusive qualification service offered for each unit, laboratories can benefit the 40 years experience of Erlab in offering alternative protection devices for laboratory technicians against chemical hazards.


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

Expomed Eurasia

Apr 25 2024 Istanbul, Turkey

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

SETAC Europe

May 05 2024 Seville, Spain

InformEx Zone at CPhl North America

May 07 2024 Pennsylvania, PA, USA

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

View all events