Laboratory Products

  • The Easy Dosing Pump for Aggressive and Corrosive Liquids

The Easy Dosing Pump for Aggressive and Corrosive Liquids

May 28 2019 Read 225 Times

Dosing very aggressive and corrosive liquids in laboratories is a challenge. Diaphragm pumps are the ideal tool for this difficult task.

The new SIMDOS® 02 FT (PTFE) has been especially developed for the transfer of aggressive chemicals. To do this, the SIMDOS® 02 FT is fitted with a PTFE head, a PTFE-covered diaphragm, and chemically resistant FFKM Kalrez® valves. An optionally available Chemraz®-valve kit even allows using the pump with highly concentrated acids such as nitric, sulphuric and hydrochloric acids and solvents such as TFH, DMF, DMSO and MEK. The pump head is situated outside the splash-protected IP-65 housing, providing a very significant safety feature.

Also available with heads in PP or PVDF, the new SIMDOS® 02 FT dosing pump transfers liquids with a flow rate of 30 µl to 20 ml/min, and dose volumes of 30 µl up to 999 ml. Following calibration, repeatability is +/-1% (full range) and the pump offers excellent long-term stability and consistent reliability throughout entire processes. The SIMDOS® 02 FT is safe to run dry and is self-priming up to 2 m. It is effective against pressures of up to 6 bar and transfers viscous media up to 150 centistokes. The integrated software permits the transfer parameters to be modified for a range of different viscosities at the touch of a button. Thanks to its neat design and small footprint, the new SIMDOS® 02 FT dosing pump takes up very little valuable laboratory space.

SIMDOS® 02 FT highlights include: FT head / FFKM valves for aggressive and corrosive liquids; intuitive operation; fast and simple calibration; pause function without data loss; adjustable transfer parameters; splash-protected design for increased safety; minimal footprint.

For further information please click here.

Reader comments

Do you like or dislike what you have read? Why not post a comment to tell others / the manufacturer and our Editor what you think. To leave comments please complete the form below. Providing the content is approved, your comment will be on screen in less than 24 hours. Leaving comments on product information and articles can assist with future editorial and article content. Post questions, thoughts or simply whether you like the content.

Post a Comment




Digital Edition

International Labmate November 2019

November 2019

In This Edition Articles - Translating Proteomic MALDi Tissue Typing to Clinical Pathology - Fusion Protein Complexes Analysed by CG-MALS - The Separation and Purification of Glutamine Deri...

View all digital editions

Events

Miconex

Nov 25 2019 Beijing, China

IFAT India

Dec 05 2019 New Delhi, India

Nepal Lab

Dec 13 2019 Kathmandu, Nepal

SLAS 2020

Jan 25 2020 San Diego, CA, USA

Arab Health

Jan 27 2020 Dubai, UAE

View all events