The Magritek Spinsolve high-resolution benchtop NMR spectrometer can be installed directly in a fume hood of a chemistry lab to monitor the progress of chemical reactions on-line. Reactants can be pumped in continuous mode from the reactor to the magnet and back using standard PTFE tubing.

The reaction itself can be carried out at temperatures of up to about 100°C. When the reaction mixture is pumped through the bore of the magnet using 2 mm o. d. PTFE tubing, it naturally cools down to 30°C or lower as it flows along the length of the tubing at room temperature. For reactions where maintaining the elevated temperature is critical, Magritek has put together a simple but effective flow set-up for on-line monitoring. It comprises a Dewar of 5 mm o. d. and 2.25 mm i. d. that is mount­ed in the bore of the Spinsolve to minimise any heat transfer from the flowing sample to the magnet. The pump, which can be set to operate in continuous or stop-flow mode to acquire points with a time resolution of about 15 seconds, is placed in the flow-loop after the magnet in order to minimise the tubing length that goes from the reactor to the sensitive volume of the Spinsolve.

This approach to reaction monitoring has been demonstrated on a number of classical chemical reactions. For example, acetalisation is a common reaction in organic synthesis where an acetal is produced from an aldehyde and an alcohol. In the example here, acetaldehyde reacts with methanol to produce acetaldehyde dimethyl acetal. The reaction was performed in DMSO to prevent evaporation. With data being collected every fifteen seconds over a total period of one hour, the user could follow waterfall plots to show the decrease of acetaldehyde as it was used up together with the corresponding rise of the acetaldehyde dimethyl acetal.

These and many other reaction systems are described in the growing library of applications notes and case studies which are freely available for downloading from the Magritek website.


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

SETAC Europe

May 05 2024 Seville, Spain

InformEx Zone at CPhl North America

May 07 2024 Pennsylvania, PA, USA

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

ChemUK 2024

May 15 2024 Birmingham, UK

View all events