Reaction Monitoring Experiments for Benchtop NMR Spectrometers Announced

Mass spectrometry & spectroscopy

Reaction Monitoring Experiments for Benchtop NMR Spectrometers Announced

24 Jul, 2014

Published over 11 years ago. See the latest and most current information on Mass spectrometry & spectroscopy.

The Magritek Spinsolve high-resolution benchtop NMR spectrometer can be installed directly in a fume hood of a chemistry lab to monitor the progress of chemical reactions on-line. Reactants can be pumped in continuous mode from the reactor to the magnet and back using standard PTFE tubing.

The reaction itself can be carried out at temperatures of up to about 100°C. When the reaction mixture is pumped through the bore of the magnet using 2 mm o. d. PTFE tubing, it naturally cools down to 30°C or lower as it flows along the length of the tubing at room temperature. For reactions where maintaining the elevated temperature is critical, Magritek has put together a simple but effective flow set-up for on-line monitoring. It comprises a Dewar of 5 mm o. d. and 2.25 mm i. d. that is mount­ed in the bore of the Spinsolve to minimise any heat transfer from the flowing sample to the magnet. The pump, which can be set to operate in continuous or stop-flow mode to acquire points with a time resolution of about 15 seconds, is placed in the flow-loop after the magnet in order to minimise the tubing length that goes from the reactor to the sensitive volume of the Spinsolve.

This approach to reaction monitoring has been demonstrated on a number of classical chemical reactions. For example, acetalisation is a common reaction in organic synthesis where an acetal is produced from an aldehyde and an alcohol. In the example here, acetaldehyde reacts with methanol to produce acetaldehyde dimethyl acetal. The reaction was performed in DMSO to prevent evaporation. With data being collected every fifteen seconds over a total period of one hour, the user could follow waterfall plots to show the decrease of acetaldehyde as it was used up together with the corresponding rise of the acetaldehyde dimethyl acetal.

These and many other reaction systems are described in the growing library of applications notes and case studies which are freely available for downloading from the Magritek website.

ILM Guide 2026/27

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Envirotech Online
EU ETS benchmark update puts industrial emissions data under sharper scrutiny
Explore more Arrow
Pollution Solutions Online
Next-generation reverse osmosis membranes for more efficient and cost-effective seawater desalination
Explore more Arrow
Petro Online
New test method ASTM D8606 has been officially released
Explore more Arrow
Chromatography Today
Non-invasive flowmeters for real-time monitoring
Explore more Arrow