How Choice of Reactor Vessel Affects Reaction Performance

Laboratory products

How Choice of Reactor Vessel Affects Reaction Performance

07 Oct, 2016

Published over 9 years ago. See the latest and most current information on Laboratory products.

Asynt has produced a new report that compares the thermal performance and advantages of vacuum jacketed versus non-vacuum jacketed reaction vessels.

Data is presented for vacuum jacketed and non-vacuum jacketed reaction vessels connected to a Julabo Presto A30 temperature control system. The report demonstrates that a vacuum jacketed vessel not only achieved faster rates of cooling but was also able to maintain a reaction at -20°C compared to just -15°C for the non-vacuum jacketed vessel. Beneficially, also using a vacuum jacketed vessel was shown to eliminate ice formation on the outside of the reactor glass (a common problem with non-vacuum jacketed reaction vessels), allowing continuous viewing of the reactor contents.

By reducing heat loss / gain a glass vacuum jacket enables faster rates of heating and uses less energy to cool the system, thereby enabling lower temperatures to be achieved than reactor vessels without a vacuum jacket. The report concludes that using a vacuum jacketed reaction vessel will allow you to optimise thermal performance thereby improving control of reactions. In addition, the report proposes that the small additional cost of a vacuum jacketed vessel is easily justified not only by the additional performance but also by the cost saving of being able to use a lower powered temperature control system.

Vacuum jacketed reaction vessels are available as options for the Asynt ReactoMate Pilot (5-50 litres) and for the Asynt ReactoMate Datum (100ml - 5 litres) reactor systems.

For a copy of the report and further information on vacuum jacketed reactor systems please visit http://www.asynt.com/product/vacuum-jacketed-reaction-vessels/.

Latest News

ILM 51.5 July 2026

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Envirotech Online
New civil penalties and real-time monitoring raise the bar for water company compliance
Explore more Arrow
Pollution Solutions Online
Energy efficiency first: Why shipping must act now while low-GHG fuels scale
Explore more Arrow
Petro Online
Fifty years on, the EU reaffirms its commitment to Seveso-level industrial safety oversight
Explore more Arrow
Chromatography Today
Unlock high-resolution analysis of therapeutic oligonucleotides
Explore more Arrow