Mass spectrometry & spectroscopy
Lubricant, Olive Oil, Motor Oil - Test viscous liquids with the Specac Pearl
Jan 12 2016
The latest innovation from our Brit-lab engineers at Specac is The Pearl, a new liquid FTIR transmission analysis essential.
The Pearl houses all fluid consistencies, no mess and no fuss. With a pipette or with a syringe, users can introduce a liquid sample and clean up in seconds.
Today we’re specifically looking at the testing of viscous liquids such as oils and greases. This brief application note will go through The Pearl’s following processes and benefits:
- Introduce sample (quickly)
- Test sample (accurately)
- Clean Pearl (easily)
Introduction
Find a viscous liquid to sample. Don’t spill it. Pull out The Pearl’s sample drawer and open the Oyster Cell by lifting-and-tilting its upper window. With a pipette, introduce a small amount of the sample onto the lower window of the Oyster Cell. When you close the Oyster Cell, the liquid cavity is sealed between the top and bottom windows. Close and check through the top window for any bubbles or other visible sample imperfections. If you’re happy, close the sliding drawer and prepare to test. Done.
Testing
The lower window in the Oyster Cell is interchangeable. Changing this lower window allows you to choose an optimum pathlength and whether you’d like the two windows parallel to each other or at a wedged angle. A wedged angle guarantees no fringing pattern when you measure an empty cell.
In our example, we tested cooking oils. We used a Shimadzu IR Affinity spectrometer to collect data. 16 scans were obtained at 4m-1 resolution, using the DTGS detector for all samples run. We fitted the appropriate 50 micron or 100 micron pathlength wedged Oyster Cell, then tested the empty Oyster Cell to collect a reference background spectrum We changed the lower Oyster Cell window twice to adjust pathlength. Window assembly P/N GS33221 for 50 micron, P/N GS33222 for 100 micron.
Cleaning
Collect your spectral reading, open the sliding tray, open the hinged Oyster Cell by lifting-and-tilting the top window and wipe the Oyster Cell windows clean. Use a soft lens cleaning-type tissue, moistened with a suitable solvent if needed. Then wipe with a dry lens cleaning-type tissue. Now you’re ready for your next sample.
If only all cleaning was this easy. Get in touch for more info.
Final word
Most people dread setting up and cleaning up, but we’ve reduced those steps to moments. Just don’t spill oil on the floor, because The Pearl can’t fix that and it’s very slippy.
Please view our video
Digital Edition
ILM 50.3 April 2025
May 2025
Chromatography Articles - Optimising two-step purification: Key considerations for sample pump setups Mass Spectrometry & Spectroscopy Articles - Detecting pharmaceuticals and their transf...
View all digital editions
Events
InformEx Zone at CPhl North America
May 20 2025 Philadelphia, PA, USA
May 21 2025 Birmingham, UK
May 27 2025 Basel, Switzerland
Jun 01 2025 Baltimore, MD, USA
Jun 04 2025 Koeln, Germany