• Infinite Latitude in AAS with only One Light Source

Laboratory Products

Infinite Latitude in AAS with only One Light Source

Sep 08 2010

The use of a xenon lamp as a continuous source of radiation opens up the entire wavelength range relevant for AAS for the customer in just one step. Previously, individual methods predominated; now the sequential multi-element analysis has become standard. This provides enormous savings in time and cost of materials.

The contrAA® series – High-Resolution Continuum Source AAS – represents previously unattained effectiveness and quality of measurement results.

The series comprises two instruments:
contrAA® 300, the high-resolution continuum source AAS for flame and hydride technology

contrAA® 700, a compact, versatile system for flame, hydride and graphite furnace technology, capable of analyzing liquid as well as solid samples in one single instrument.

Both systems combine intelligent design with premium functionality and persuasive performance characteristics:

  • Just one light source for all elements
  • Sequential multi-element routine as standard
  • Unique simultaneous background correction
  • High sample throughput
  • Rapid readiness for measurement
  • Easy to operate and robust
  • New information content
  • Improved analytical performance

Infinite Latitude with only One Light Source
With only one light source for all elements and all available wavelengths, the instrument is ready to measure at all times. The previous dependence of the measurement on hollow cathode lamps is eliminated and the associated costly preparation time no longer applies. The protracted burn-in time of the light source, necessary for conventional line sources, is now also no longer required, since any drift phenomena are corrected simultaneously. The use of a xenon lamp as a continuous source of radiation opens up the entire wavelength range relevant for AAS for the customer in just one step. Previously, individual methods predominated; now the sequential multielement-routine has become standard. This provides enormous savings in time and cost of materials.
The evaluation of molecular absorption bands, allowing the analysis of additional elements, such as sulfur or phosphorus, is a further innovation.

Impressive Design
Intelligent design goes beyond saving space in the laboratory and beyond convenient transportation. Today it really means readiness to operate quickly, high effectiveness and easy handling as a means of minimizing service and operating costs. Operating convenience is a top priority for the contrAA®. Thanks to the tandem principle, it is readily possible to change quickly from flame technology to graphite furnace technology and vice versa, depending on the task to be accomplished. Cumbersome installation or additional adjustment is now no longer required!

Unique Resolution
The unique resolution with a spectral bandwidth of below 2 pm/ pixel is decisive for the new quality of the measurement results. Interference is minimized through optimum line separation. Errors, which were caused by the limits of the resolution in traditional line AAS, can be identified for the first time and thereby avoided.

Click Here for more information


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

SETAC Europe

May 05 2024 Seville, Spain

InformEx Zone at CPhl North America

May 07 2024 Pennsylvania, PA, USA

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

ChemUK 2024

May 15 2024 Birmingham, UK

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

View all events