• Balance Series Features Static Charges Removal Device for Accurate Weighing

Laboratory Products

Balance Series Features Static Charges Removal Device for Accurate Weighing

Oct 08 2018

Weighing is the most commonly performed task in any laboratory. There are many types of balances that are being used for this purpose, they differ in capacities and readabilities but all of them are sensitive to harsh environment conditions. There are many factors that influence the weighing results. If the balance's location does not comply with the guidelines of good weighing practices, there is a high probability that results are not going to be repeatable or accurate each time a weighing is performed. Air drafts, temperature changes, direct exposure to sunlight or even lack of proper maintenance of the balance might cause the results to be simply wrong. The better/higher the readability of the balance is, the higher the chances of incorrect results negatively affecting the whole weighing or research process etc.

One of the factors having a direct, negative effect on weighing results are static charges. They cannot be seen but are influencing adversely the weighing results if present. Mistakes in readouts are more likely and more significant if the balance's readability reaches up to 4th or 5th decimal place, however not only analytical and semi-micro balances are prone to it. Elimination of static charges might require increasing relative humidity in the room, changing the way of storing samples or weighing boats, or using external devices. Ohaus Explorer Semi-Micro balances have a built-in ioniser as standard in selected models, there is also a standalone ioniser available as an accessory.

The newly launched Pioneer PX balances have been equipped with a feature helping to eliminate static charges too. On the top of the draftshield there is a red bar located – it is a static charges removal device that is made of dissipative ABS. No additional power or connection is needed to make it work. Elimination of static charges requires just touching the bar with the object that requires grounding.

"For an entry level balance such as Pioneer PX this feature is unique and aimed at helping the users to obtain the most accurate results every time," said Szymon Hołubowicz, Senior Market Manager at Ohaus Europe GmbH. "Users can now be sure that their results are correct even using equipment prone to cumulating static charges".

Pioneer PX balances were launched on 9th of July 2018. Learn more about them on ohaus.com


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

Expomed Eurasia

Apr 25 2024 Istanbul, Turkey

AOCS Annual Meeting & Expo

Apr 28 2024 Montreal, Quebec, Canada

SETAC Europe

May 05 2024 Seville, Spain

InformEx Zone at CPhl North America

May 07 2024 Pennsylvania, PA, USA

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

View all events