• RSA Glass™ – Reduced Surface Activity Glass A next generation of glass reduces the interaction of analytes and the glass.

Laboratory Products

RSA Glass™ – Reduced Surface Activity Glass A next generation of glass reduces the interaction of analytes and the glass.

Oct 05 2011

• Prevent pH changes in vials before injection
• Detect Low Abundance Analytes Normally Adsorbed by Glass
• Prevent hydrolysis that can occur in your vials

Made with a new patent pending, glass manufacturing process, RSA Glass™ vials and inserts have reduced surface activity for basic compounds. This is due to the elimination of virtually all silanols (hydroxyl groups) that can have deleterious effects on your analytes and sample solutions.

RSA™ autosampler vials and glass inserts are not manufactured with coatings; but have significantly reduced silanols on the glass surface normally produced during the manufacturing process. This lack of surface silanols makes them an excellent choice for GC and GCMS applications.

With standard borosilicate glass vials and inserts sample diluents (such as water) can de-protonate the many surface hydroxyl groups; producing a negative charge on the glass wall. The “acidic” functionality of silanols has been known to cause adsorption of basic compounds, change the sample solution pH and/or hydrolyze susceptible compounds rendering them undetectable. With RSA Glass™ vials and inserts there is virtually no sample “loss to the vial” and no “pH shifting” making your analysis more reliable.

If you are working with low abundance basic samples with regular glass vials, it is very possible that your compounds could easily be adsorbed to the glass wall. This can change your quantitation or completely remove the compound from solution preventing injection and ultimately masking its detection and identification. With RSA Glass™ vials and inserts this will not occur if the adsorption is due to silanol interaction.

If you are working with sensitive compounds commonly found in natural products, biological samples or chemical synthesis, the glass wall could be a problem for basic compounds. With RSA Glass™ vials this problem is eliminated.

If you are working with basic proteins that adsorb or are affected by silanols; RSA Glass™ vials and inserts will be a good solution for you. If your proteins are sticking to the glass due to adsorption to the siloxane surface, RSA Glass™ provides an almost completely silanized surface. The results of silanizing RSA Glass™ over standard borosilicate glass is far superior for proteins and peptides if this option is desired.

RSA Glass™ has been tested for metals that may cause sample or diluent contamination. It has ULTRA low levels of Sodium, Calcium, Aluminum and Boron. Sodium and Boron levels are 200 to 300 times less concentrated compared to leading manufacturers with Calcium and Aluminum almost non-detectable. Testing was done using ICP with water from the vials and a 4 hour "soak" time.

There is no significant cost increase for RSA Glass™ vials and inserts. They are QC tested to meet or exceed any commercially “certified” vial or insert. That is our promise. Manufacturer MicroSolv. Patent Pending.
For further information on RSA vials contact Hichrom Limited, UK, Tel: +44 (0) 118 930 3660 technical@hichrom.co.uk or click here
 


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

InformEx Zone at CPhl North America

May 07 2024 Pennsylvania, PA, USA

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

ChemUK 2024

May 15 2024 Birmingham, UK

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

Discovery Europe 2024

May 22 2024 Basel, Switzerland

View all events