The KERN DBS halogen moisture analyser provides steady, reliable results with high reaction speed, even with delicate samples. It stores the measurements on the one hand in the device and on the other it transfers them via USB or RS 232 data interface to the required PC or printer.
The KERN DBS moisture analyser from KERN & SOHN / Germany uses the thermogravimetric principle to carry out the measurement: i.e. an integrated balance records the starting weight of the sample first. A heating unit then dries the sample, while the weight is continuously recorded. As a result of this process, the weight loss is interpreted as moisture content. With this principle, the device achieves a measurement accuracy of up to +/- 0.01 percent, depending on the size of the sample.
The integrated balance is based on a weighing cell from the new Single-Cell Generation made from aluminium alloy. Thanks to short stabilisation times and high temperature resistance, this cell made from a single piece of metal indicates the weighing result significantly quicker than other weighing systems.
The KERN DBS uses the radiation of a halogen-quartz glass heater with a power of 400 W for drying. Sensitive temperature control thanks to halogen technology ensures uniform heating of the sample and is therefore also suitable for thermo-sensitive samples. The device switches off automatically or is time-controlled, depending on the settings. Temperature ranges from 50 to 200 degrees, as well as different heating profiles mean that you can adapt the procedure precisely to a particular sample. The results are measurements that are both reliable and quick.
The drying programs at a glance:
You can store up to ten drying programs in the moisture analyser with parameters, such as, for example, drying period and temperature, display settings, switch-off criteria, etc. This saves the user time and guarantees repeatable results. Using a range of features, it is simple for these results to be documented, processed further and tracked:
In order for the comparability of the results of moisture analyses to be guaranteed in the long term, the correct temperatures must be maintained in the heating chamber of the device or in the sample. KERN therefore offers its customers regular calibration of their moisture analyser - for genuine, reliable measuring results. If requested, the provider will also carry out sample analyses and provide support when setting up the parameters for the device.