• Software Update for NMI Microscope System

Microscopy & Microtechniques

Software Update for NMI Microscope System

Feb 11 2010

Further software functions have now been added to the NMI (Non Metallic Inclusions in Steel) Microscope System from Carl Zeiss. The easy-to- use system makes steel analysis even more comfortable and convenient.

The expanded NMI system now offers considerably simplified image acquisition, a particular benefit for variable regions of interest on the sample, and automated segmentation of the inclusions. The operation of all functions is very straightforward. The software now includes a gallery for the visualisation of oversized inclusions, with which the measured data and image can be displayed simultaneously. The updated version of NMI can also be combined with the recently launched upright Axio Imager.Z2m respectively Axio Imager.M2m versions of the microscope stand.

NMI has implemented the EN 10247 standard for classifying the content of non-metallic inclusions in steel, but also fulfils the requirements of the DIN 50602, ASTM E 45, ISO 4967 and JIS G 0555 standards. It is offered as a complete system and enables automatic microscopic analysis of steel purity for up to six samples.

The function enabling result comparison is of particular benefit as quality determination according to the EN 10247 standard is based on mathematical calculations instead of comparative diagrams. The results of the samples measured in a series can be output individually or in combination. The software offers the possibility of performing the measurement in large mosaic images composed of single images. This means that inclusions are not cut off at the image edge, but are recorded in their entirety and are therefore correctly classified.

NMI makes automatic sample evaluation very fast, also if the sample is to be measured in accordance with several standards. This is all possible in a single measuring procedure.

The system can be expanded with further image analysis applications, e.g. for grain size and particle analysis. System solutions with the motorised upright microscopes of the Axio.Imager series respectively the Axio Observer.Z1m inverted microscope offer optimal conditions for accurate, convenient measurements.


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

SETAC Europe

May 05 2024 Seville, Spain

InformEx Zone at CPhl North America

May 07 2024 Pennsylvania, PA, USA

ISHM 2024

May 14 2024 Oklahoma City, OK, USA

ChemUK 2024

May 15 2024 Birmingham, UK

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

View all events