• Increased Reliability and Accuracy in Optical Metrology

Microscopy & Microtechniques

Increased Reliability and Accuracy in Optical Metrology

Mar 02 2012

The Olympus LEXT OLS4000 is being used for the development of good practice guidelines and new calibration standards in optical metrology. These reference standards are being developed by a team led by Professor Richard Leach, Principal Research Scientist at the National Physical Laboratory (NPL). Preliminary data, presented by Professor Leach at the 10th International Symposium on Measurement Technology and Intelligent Instruments (ISMTII) demonstrated that these calibration standards will help users to eliminate background noise and data uncertainties, thus increasing reliability and accuracy. The good practice guide on the calibration of confocal microscopes will also provide input to the upcoming ISO/WD 25178-607 specification standard, which is currently in development.

As an important component of these calibration standards, Professor Leach’s team is defining good practice guidelines using typical examples of: stylus instruments; white light interferometers; focus variation instruments; and confocal microscopes. This project has established robust and easy-to-use calibration steps and referencestandards for all the major areal surface measurement  instrumentation technologies. As part of this, NPL is developing a box of artefacts (optical flat, step heights, lateral grids, star patterns, sphere on plane, deterministic) to allow calibration in compliance with the latest draft ISO standard. Once finalised, users can implement these to gain a level of confidence in the accuracy and trueness of their resulting data.

Further demonstrating the reliability and accuracy of the LEXT OLS4000, Mr Hitoshi Suzuki, Olympus Corporation, Japan presented his findings on ‘A study of surface measuring limitation on a laser scanning microscope by the examination of response properties of surface texture and slope detection on a ruby sphere sample’, at the EUSPEN conference in May. Since identifying and rejecting doubtful measurements is key to maintaining accuracy, instruments need to be able to produce repeatable results. Accuracy when using a CLSM depends on the numerical aperture (NA) of the objective lens; steep slope measurements up to 80º can be accurately obtained with the LEXT OLS4000 when using a 0.95 NA lens.


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

ChemUK 2024

May 15 2024 Birmingham, UK

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

Discovery Europe 2024

May 22 2024 Basel, Switzerland

NGVS 2024

May 23 2024 Beijing, China

View all events