• Highly sensitive targeted and non-targeted HPLC-MS PFAS analysis
    Figure 1: Highly sensitive targeted and non-targeted HPLC-MS analysis of PFAS.
  • Figure 2: Total ion chromatograms (TIC) of the soil sample measured in triplicate.
  • Figure 3: Ion trace correspondent to SF5(CF2)9SO3- with m/z 656.8927 +/-20 ppm.

Columns

Highly sensitive targeted and non-targeted HPLC-MS PFAS analysis

Per- and polyfluoroalkyl substances (PFAS) are persistent environmental pollutants known for their long lifetime and mobility. Their stability leads to accumulation in groundwater and soil, with proven harmful health effects. This technical note presents a method for identifying and quantifying PFAS using a YMC-Triart C18 HPLC column. This column, based on a robust hybrid silica particle, offers enhanced separation of isomers and improved analytical performance when coupled with mass spectrometry.

PFAS standards could be well resolved by the YMC-Triart column. Notably, partial separation of PFOS and PFHxS isomers within 10 seconds facilitated fragmentation pattern analysis for structural elucidation.

Non-targeted analysis in a soil extract

To evaluate performance in complex matrices, a soil extract from a contaminated site (Brilon-Scharfenberg, Germany; from the scientific publication of Zweigle et al. [1]) was analysed. Total ion chromatograms (TICs) from triplicate measurements (Figure 2) revealed consistent profiles, despite the high matrix complexity.

The YMC-Triart C18 column achieved effective separation of PFAS, including improved partial resolution of isomers compared to Zweigle et al. [1]. For instance, SF5(CF2)9SO3 isomers were separated (Figure 3), enabling the acquisition of distinct fragmentation spectra. The larger fragments in longer retention indicate an exclusively linear isomer. Specifically, the shorter retention time and the smaller fragments suggest a branched isomer or a differently positioned SF5-group.

Conclusion

The YMC-Triart C18 column demonstrates robust performance for PFAS analysis. It delivers:

  • Efficient separation of key PFAS standards with linear quantification
  • Reproducible results in complex matrices, such as soil extracts
  • Improved isomer separation, enabling structural elucidation through distinct fragmentation patterns

The column provides a reliable and enhanced approach to targeted and non-targeted PFAS analysis, supporting environmental monitoring and regulatory compliance.

Download the Technical Note for full details.

More information online

References:

1. Environ. Sci. Technol. 2023, 57, 6647−6655.


Digital Edition

Lab Asia 32.1 Feb 2025

February 2025

Chromatography Articles - Comparing volumetric and thermal flowmeters for assessing and validating liquid chromatography performance Mass Spectrometry & Spectroscopy Articles - The importa...

View all digital editions

Events

SPS Smart Production Solutions Guangzhou

Feb 25 2025 Guanghzou, China

SmartLab Exchange

Feb 25 2025 Amsterdam, Netherlands

Nepal Lab

Feb 27 2025 Kathmandu, Nepal

PITTCON 2025

Mar 01 2025 Boston, MA, USA

IFPAC 2025

Mar 02 2025 Bethesda, MD, USA

View all events