New Low Cost GC Flowmeter for Gas Chromatography

Gas chromatography

New Low Cost GC Flowmeter for Gas Chromatography

22 Feb, 2012

Published over 14 years ago. See the latest and most current information on Gas chromatography.

Ellutia are pleased to launch the 7000 GC Flowmeter for use in gas chromatography. Accurate and repeatable gas flow measurements are a crucial part of obtaining good results from your Gas Chromatograph. The new 7000 GC Flowmeter makes gas flow measurement easier and more accurate, helping to eliminate user errors.

“We are very excited to be able to offer the 7000 GC Flowmeter at a price point significantly lower than other models on the market. We hope that this low price will allow chromatographers who previously could not justify the expense of other higher priced flowmeter’s the chance to  have access to this valuable tool,” said Phillip James, Managing Director at Ellutia.

Creating a follow up to the best selling 6000 Flowmeter was never going to be easy, but by listening to customer feedback the new 7000 GC Flowmeter has a number of improvements over its predecessor. The pocket-sized unit is now  a more ergonomic design, smaller (130 x 68 x 30 mm), lighter (150g), features a built in rechargeable battery and a full colour OLED display. Despite the reduction in size the Flowmeter still offers the analytical performance expected.

The 7000 GC Flowmeter possesses a 25 point calibration traceable to UKAS standards, to ensure the level of accuracy required in a professional laboratory. Users are able to set the temperature and pressure of their working environment and the 7000 GC Flowmeter will automatically compensate for  these changes from its calibration conditions.

The Ellutia 7000 GC Flowmeter provides as standard, measurement in ml/min of eight gases commonly used in gas chromatography. In addition to the standard flow measurement mode the 7000 GC Flowmeter also features several modes designed specifically for the GC user.

Linear Velocity mode allows the user to set their column diameter and then display the average column velocity in cm/sec. Split Flow mode allows the user to see a live display of both the split flow and split ratio.

• Measures flows of Nitrogen, Air, Helium, Hydrogen, Carbon Dioxide, Oxygen, Argon and Argon/5% Methane

• Resolution of 0.1 ml/min

• Range of 0.1 to 500 ml/min (0.1-275 ml/min for CO2) Accuracy ± 2.5% or 0.4 ml/min

• Calibration traceable to UKAS Standards

Latest News

LMUK 51.7 Nov 2026

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Envirotech Online
Advances in vapour filtration lead to cleaner air and cleaner measurements
Explore more Arrow
Pollution Solutions Online
New operational discipline needed to meet regulations in South East Asia
Explore more Arrow
Petro Online
PFAS reference standard combines ten analytes to support trace-level calibration
Explore more Arrow
Chromatography Today
High-load peptide purification
Explore more Arrow