N2 generators for LCMS, MP-AES, GC and general applications

Gas chromatography

N2 generators for LCMS, MP-AES, GC and general applications

13 Jun, 2013

Published over 13 years ago. See the latest and most current information on Gas chromatography.

F-DGS I has taken huge steps to improve the functionality of its N2 generators. We have re-designed its core range of N2 gas generators and implement a series of unique features and end user benefits, making our N2 range, the most complete one and the best in the market.

Our Nitrogen gas generators are quieter, more efficient, technically advanced in terms of safeguards and offer the user more functionality in control than anything else on the market.

For LCMS applications, we can also offer both PSA and Membrane technology depending on the application and end user preference. The flow rate range allows single or multiple instruments to be supplied.

Our PSA MAESTRO LCMS series exists in 6 models with the option with or without built in air compressor:

- MAESTRO-35 LCMS series: with max. Output of 35 L/min of N2 gas

- MAESTRO-64 LCMS series: with max. Output of 64 L/min of N2 gas

- MAESTRO- DF LCMS series: The dual flow, specifically designed for the Agilent 6400 & 6500: to meet the drying, sheath, nebulisation and collision gas requirements. The generator provides two continuous streams of nitrogen from a single ‘plug & play’ unit.

- MAESTRO-25 LCMS series: with max. output of 25 L/min of N2 gas

- MAESTRO-15 LCMS series: with max. output of 15 L/min of N2 gas

- MAESTRO- TF LCMS series: the triple flow, specifically designed to supply Curtain, Source & Exhaust gases with dry air and nitrogen for AB Sciex LCMS instruments.

The THYSTER MP-AES dual flow generator has been specifically designed to meet the nitrogen and dry air needs to supply a Microwave Plasma Atomic Emission Spectrometer (MP-AES) of the Agilent range. It is complete plug and Play system.

CONFIGURATION FOR ORGANICS ANALYSIS

N2: 25 L/min at 65 psi, purity > 99.7%

Air: 36.5 L/min at 87 psi separate in 3 ways for POP, EGCM and monochromatic gas

CONFIGURATION FOR DETERMINATION OF SULPHUR

N2: 25 L/min at 65 psi, purity > 99.7%

Air: 36.5 L/min at 87 psi separate in 2 ways for POP and EGCM optic purge

N2: 10L/min @99.95% at 65 psi to supply monochromatic gas

For GC application and general application, we employ PSA technology to deliver best in class life expectancy. An integrated oil-free compressor is optional, but all generators provide N2 at purities ranging from 98% to 99.9995%. Zero Nitrogen and Combine N2/AIR generators are available for more specific GC applications.

Latest News

ILM 51.5 July 2026

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Envirotech Online
Throwable sensor offers rapid remote detection of chemical threats
Explore more Arrow
Pollution Solutions Online
Energy efficiency first: Why shipping must act now while low-GHG fuels scale
Explore more Arrow
Petro Online
Tunable infrared chip could sharpen gas leak and pollution detection
Explore more Arrow
Chromatography Today
SLAS Technology Volume 38 highlights AI-driven laboratory automation, transcriptomics and gene therapy
Explore more Arrow