• Advanced Bio Filters Setting New Benchmarks

Laboratory Products

Advanced Bio Filters Setting New Benchmarks

Jan 04 2012

Diversified technology company 3M has launched a range of bioburden reduction filters combining the high filtration performance of membrane-type media with enhanced flow characteristics, enabling lower system costs and longer operating lifetimes.

The new LifeASSURE PNA Filter Series from 3M’s Purification division can be used as pre-filters or final filters, where a high level of microbiological control is required.

They are designed specifically for biotech, pharmaceutical and biological applications, such as production of vaccines, laboratory fluids, blood products, fine or bulk chemicals, and purified water.

“The advanced technologies we have engineered into the new LifeASSURE PNA Filter Series will enable customers in the bioprocess, pharmaceutical and other sectors to reduce capital costs and operating overheads whilst simultaneously benefiting from improved microbiological control,” said Andrew Whitehouse, Sales and Marketing Manager for 3M‘s Purification division.

LifeASSURE PNA filter assemblies are available with either a 0.2μm or 0.45μm filtration rating and feature an asymmetric membrane with 3M’s Advanced Pleat Technology (APT) that maximises the useful surface area of the filter. In addition, optimised filter-media support layers are positioned upstream and downstream of the membrane.

Together, these innovations increase flow rate per unit pressure, allowing designers to meet performance targets using fewer cartridges thereby enabling smaller, lower-cost systems. In continuous operation mode the filters achieve longer service lifetimes, saving the costs associated with frequent filter changes. In batch process applications, the higher flow rate can help reduce the number of filters needed to process a given batch volume.

Moreover, tests confirm superior reduction of microorganisms. The 0.2μm PNA020 membrane provides Log Reduction Values (LRV) in excess of 7 with B. diminuta (ATCC 19146) at a challenge concentration of at least 10 7cfu/cm”, while the 0.45μm PNA045 filter achieves an LRV greater than 8 for S. marcescens (ATCC 14756) at 10 6cfu/cm” or higher.


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

Discovery Europe 2024

May 22 2024 Basel, Switzerland

NGVS 2024

May 23 2024 Beijing, China

Analiza

May 28 2024 Tel Aviv, Israel

View all events