New Addition to Humidity Control System with Support for Nitrogen Gas Announced

Mar 18 2019

The RH95 Relative Humidity Controller provides precise environmental sample control to Linkam’s range of temperature stages. Since its introduction, there have been many applications found ranging from testing and characterising new photovoltaic materials, research into new battery technologies to the characterisation of pharmaceuticals. The RH95 can be used to control humidity inside one of Linkam’s many temperature stages or other sealed chamber up to a volume of 2000 ml from 5 to 90% RH. Unlike other humidity control systems, no costly dry air supply is required. Ambient air is dried through a specially designed automatic recycling desiccant system and so can be left controlling humidity for months at a time.

Rather than simply monitoring the humidity of the air supplied to the chamber, a sensor is mounted inside the chamber to create a feedback loop to the controller, ensuring precise control. Humidity can have a significant effect on the properties of a material. These include cosmetic surface effects to changes in a sample’s mechanical properties and chemical changes such as creating polymorphs. Such experiments can be performed with the RH95 and Linkam heating cooling stages such as the LTS420 and THMS600 or the TST350 tensile stage.

Linkam have introduced a custom-designed gas regulator for the RH95 controller. As well as drawing air through the chamber, users now have the option to use nitrogen as the carrier gas for the water vapour The regulator allows the use of bottled or piped nitrogen gas with up to 5Bar input, which is automatically regulated down to a safe level for use with the RH95.The use of nitrogen as a carrier gas is important for studies where researchers want to remove the effects of oxidation and corrosion that may be caused by oxygen in ambient air. This opens up a whole new range of applications and experiments for the RH95 such as isolation studies.

For further information please click here.


Digital Edition

Lab Asia 30.2 - April 2023

April 2023

In This Edition Chromatography Articles - On-Column Sample Focussing: a Personal Perspective Mass Spectrometry & Spectroscopy Articles - Multi-scale, multi-modal and operando imaging wi...

View all digital editions

Events

MSACL 2023

Apr 02 2023 Monterey, CA, USA

Analitika Expo 2023

Apr 11 2023 Moscow, Russia

Microbiology Society Annual Conference 2023

Apr 17 2023 Birmingham, UK

Korea Lab 2023

Apr 18 2023 Kintex, South Korea

Analytica Vietnam

Apr 19 2023 Ho Chi Minh City, Vietnam

View all events