Low-cost Accessory for Improved Mass Spectrometry Introduced

Mass spectrometry & spectroscopy

Low-cost Accessory for Improved Mass Spectrometry Introduced

25 Jun, 2014

Published over 11 years ago. See the latest and most current information on Mass spectrometry & spectroscopy.

Owlstone Ltd have announced the commercial launch of its UltraFAIMS series of products, developed to enhance mass spectrometry (MS) by quickly simplifying complex mass spectra, separating isobaric ions and reducing background.

UltraFAIMS is a miniaturised chip-based FAIMS (Field Asymmetric Ion Mobility Spectrometry) platform technology developed by Owlstone. UltraFAIMS can be interfaced with mass spectrometers to provide an additional in-source separation stage for isobaric analytes, protein and peptide charge states, large and small proteins, isomers and conformers. Miniaturising the chip has allowed Owlstone to generate much higher field strengths than have been available in FAIMS systems up to now. This means that a greater range of analytes can be separated, at faster speeds, without compromising the system sensitivity.

The newly-launched UltraFAIMS ion filters incorporate the miniaturised FAIMS chip, and can be retrofitted onto mass spectrometers. The low-cost modules have been shown to improve mass accuracy and detection limits, increase the level of quantitation and dynamic range, reduce background and provide additional real-time separation within LC peaks. Once installed, UltraFAIMS can be turned on to provide extra separation, or turned off to allow transmission of all species simultaneously. There is no need to remove it from the system when not in use. Its small size (height, width and depth ˜20cm) and straightforward interface mean it can easily be added to an established laboratory setup.

The product range includes: UltraFAIMS-A1, compatible with Agilent 6130/6150 (SQ), 6460 (QQQ), 6230 (TOF) and 6530/6540 (QTOF); UltraFAIMS-T1, compatible with Thermo Exactive Series & LTQ-Orbitrap; UltraFAIMS-DK1 (developer kit), which is available for instrument developers or vendors who wish to interface with a mass spectrometer or source for which an off-the-shelf interface isn’t currently available.

ILM Guide 2026/27

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Envirotech Online
EU ETS benchmark update puts industrial emissions data under sharper scrutiny
Explore more Arrow
Pollution Solutions Online
Next-generation reverse osmosis membranes for more efficient and cost-effective seawater desalination
Explore more Arrow
Petro Online
From specification to certification: Ensuring jet fuel conformity with reliable flash point testing
Explore more Arrow
Chromatography Today
Non-invasive flowmeters for real-time monitoring
Explore more Arrow