Identifying an Optimal Biofuel  

Laboratory products

Identifying an Optimal Biofuel  

24 Aug, 2014

Published over 12 years ago. See the latest and most current information on Laboratory products.

The Model 440 Elemental Analyzer from Exeter Analytical Inc is proven to provide precise percentage Carbon (C), Hydrogen (H) and Nitrogen (N) data on biomass samples in as little as 5 minutes

Identifying an optimal biofuel from crop, grass, algae or tree (biomass) samples has traditionally been laborious and painstaking.  Determining the percentage Hydrogen data enables easy calculation of the biomass sample gross or net calorific value.  With increasing global interest in 'Carbon Trading' the determination of percentage carbon provides accurate data to enable organisations (or countries) to buy and sell carbon permits as part of a program to reduce carbon emissions. The determination of the Nitrogen content of biomass samples using a Model 440 saves considerable time and cost with no diminishment of data quality compared with the traditional Kjeldahl nitrogen determination method.

The Model 440 is a static combustion CHN Elemental Analyzer, with a unique horizontal furnace design, which enables easy removal of sample residue between each biomass analysis.  Consequently one combustion tube will analyse in excess of 1000 biomass samples without the need for removal and cleaning. By comparison other elemental analysers, employing vertical furnace designs, will require cleaning after as little as 20 samples. The gas flow characteristics of the Model 440 analyser are superior to other elemental analysers due to the effective elimination of troublesome residue build-up. This thereby provides longer-term calibration stability as well as enhanced accuracy and precision for measured biomass sample data.

In addition, as the Model 440 provides complete control over combustion parameters it is able to reproducibly achieve 100% combustion with the widest range of biomass samples. Proprietary Nitrogen analysis software uniquely enables accurate measurement of low Nitrogen levels (in the 0.1-0.2% range) with a high degree of accuracy.

Latest News

Lab Asia 33.6 Dec

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Envirotech Online
The monitoring design behind the Iowa lead azine detonation
Explore more Arrow
Pollution Solutions Online
Pump and mixer service at paper mill set to reach 40 years
Explore more Arrow
Petro Online
Borings find 3.32-foot jet fuel layer beneath Joint Base Andrews hydrant piping
Explore more Arrow
Chromatography Today
Thermo-analytical GC-MS standard for microplastics in drinking water reaches final draft stage
Explore more Arrow