• Online TOC Analysis Meets New Methods of Communication

Laboratory Products

Online TOC Analysis Meets New Methods of Communication

Feb 21 2012

Shimadzu has released the new TOC-4200 online analyser. It represents a new generation that offers the ability to use new modes of communication. The TOC-4200 covers features such as web-based monitoring and Modbus  protocol for two-way digital communication, and it offers new functionality that provides a wider range of potential  applications.

Modbus two-way digital communication capability enables controlling two-way communication for multiple devices over a single integrated signal line, which also simplifies electrical wiring work. This allows connecting to two-way communication networks. The optional web-based monitoring function allows monitoring the measurement data or status of instruments from any network-connected computer in the world.

The eco mode reduces waste by only using carrier gas and operating the sampling pump when it is needed for measurements. Maintenance costs are cut by Shimadzu's unique multifunctional sample processing injection system reducing part count by integrating functions into an 8-port valve and syringe pump. Offline measurements can be performed by interrupting online measurements without stopping them. When offline measurements are finished, online measurements resume automatically. This enables more efficient offline measurements.

The TOC-4200 helps to prevent measurement interruption due to the running out of reagents or other consumables by providing notification through the communication methods such as screen and contact output when the replacement period approaches. Measurement data and calibration history can be stored in the instrument up to one year. Stored data  can be removed via USB memory and valuable measurement data can be backed up inside the instrument. An optional high-sensitivity kit enables measurements of samples with TOC concentrations below 1 mg C/L. The  high-salt sample combustion tube kit significantly increases the period between maintenance, by about 10 times,  when measuring sea water or other samples containing high salt levels. Adding the TN measurement option permitstotal nitrogen (TN) measurement with catalytic combustion and chemiluminescence detection.


Digital Edition

Lab Asia 31.2 April 2024

April 2024

In This Edition Chromatography Articles - Approaches to troubleshooting an SPE method for the analysis of oligonucleotides (pt i) - High-precision liquid flow processes demand full fluidic c...

View all digital editions

Events

Water Expo Nigeria 2024

May 21 2024 Lagos, Nigeria

Discovery Europe 2024

May 22 2024 Basel, Switzerland

NGVS 2024

May 23 2024 Beijing, China

Analiza

May 28 2024 Tel Aviv, Israel

View all events