Many rock formations contain small amounts of uranium minerals. Weathering processes release uranium into the soil, water and atmosphere. Because of its subchronic toxicity, the introduction of a limit for the uranium content of drinking and mineral water has been demanded for some time. In the European Union the corresponding limits have not yet been fixed by law. Internationally, the stipulated limiting
values range from 10 to 30 ìg/L uranium.
The accurate quantification of trace amounts of uranium generally requires complicated and expensive analytical equipment such as instruments based on inductively coupled plasma mass spectrometry (ICP-MS). In contrast, with the Metrohm 797 VA Computrace, dissolved uranium in the form of U(VI) can be determined easily and at reasonable expenditure!
The voltammetric determination of uranium with the 797 VA Computrace is just as accurate and efficient as current ICP-MS methods.
The AdCSV method (Adsorptive Cathodic Stripping Voltammetry) for the voltammetric determination of the uranium content is based on
complexing U(VI) with chloranilic acid (2,5-dichloro-3,6-dihydroxy-1,4-benzoquinone). The uranium content can be determined down to the
ng/L range. DIN Standard 38406-17 is currently being drawn up based on this AdCSV method. This means that in future the voltammetric determination of uranium can be used as a generally recognised method for monitoring drinking and mineral water in daily practice. The 705 UV Digester made by Metrohm is used for the UV photolysis of water samples with a low to medium organic load. The UV Digester consists of a control unit with builtin timer and a separate wet-chemistry part with UV lamp, cooling device and a holder for 12 sample digestion tubes, each for max. 12 mL sample.

Latest News

ILM 51.5 July 2026

Explore our Digital Edition

Discover the latest news and research

Digital edition

Explore Our Other Sites

Envirotech Online
Exhibitor registration opens for 2027 occupational safety and health trade fair in Düsseldorf
Explore more Arrow
Pollution Solutions Online
Energy efficiency first: Why shipping must act now while low-GHG fuels scale
Explore more Arrow
Petro Online
UK refining capacity falls to four plants after a second unplanned closure
Explore more Arrow
Chromatography Today
SLAS Technology Volume 38 highlights AI-driven laboratory automation, transcriptomics and gene therapy
Explore more Arrow